<p>The Melody™ transcatheter pulmonary valve (TPV) uses Ensemble™ II transcatheter delivery system to treat right ventricular outflow tract (RVOT) dysfunction.</p>
A less-invasive approach to restore valve function
Melody™ TPV therapy has been proven to relieve conduit and surgical valve obstruction, restore valve function, and delay the patient’s next surgical intervention.
A valve specifically designed for a pulmonic indication
The Melody™ TPV was the first transcatheter valve commercially approved. Since 2006, it has benefited more than 18,000+ patients globally. TPV replacement with the Melody™ valve has proven to be a safe and effective treatment for patients with RVOT conduit or surgical valve dysfunction.
The Melody™ TPV is a less invasive approach that has been proven to:
Relieve conduit and surgical valve obstruction
Restore valve function
Delay the patient’s next surgical intervention
Most medical procedures have risks. The Melody™ TPV procedure's more serious risks include: valve dysfunction, stent fracture, and endocarditis.
Optimal hemodynamics for the RVOT
Comprised of a BJV valve sutured within a platinum-iridium frame, the Melody™ valve is specifically designed to treat RVOT valve dysfunction and delivers consistent outcomes with excellent performance at more than 10 years of patient follow-up.
Natural thin leaflets open and close under minimal pressure for optimal hemodynamics in the low pressure RVOT.
Deep coaptation of leaflets provides valve competency across a range of conduit sizes and geometries, including noncircular environments.
Radiopaque stent allows for easy visualization.
Exceptional deliverability and ease of use
The Ensemble™ II transcatheter delivery system is designed for controlled, stepwise deployment of the valve with balloon-in-balloon technology.
Ensemble™ II features
Simple hand crimping and loading
Balloon marker bands aid in visualization of valve position prior to unsheathing and during deployment
Integrated sheath eliminates need for additional sheath and protects valve during delivery
A BJV valve sutured within a platinum-iridium frame
Melody™ TPV 20
16 mm BJV valve
Acceptable deployment: up to an inner diameter of 20 mm
PB1018
A BJV valve sutured within a platinum-iridium frame
Melody™ TPV 22
18 mm BJV valve
Acceptable deployment: up to an inner diameter of 22 mm
Note: To facilitate manufacturing (sewing of the tissue onto the TPV frame), the initial out-of-the-jar lengths of the two valves will differ slightly (30 mm length for PB1016 and 28 mm length for PB1018). Once crimped on the delivery system, the lengths of both TPV sizes will be the same and will remain so during deployment to any size.
Ensemble™ II transcatheter delivery system
Item number
Balloon size (mm)
French size (Fr)
Overall length (cm)
ENS1018
18
22
100
ENS1020
20
22
100
ENS1022
22
22
100
Ensemble™ II is a balloon-in-balloon catheter delivery system with a retractable polytetrafluoroethylene (PTFE) sheath covering.
Nylon inner and outer balloons are available in three sizes: 18 mm, 20 mm, and 22 mm. At inflation, the inner balloon is half the diameter of the outer balloon.
The sheath has a side port for flushing the system and a hemostatic sleeve to minimize bleeding at the insertion site.
Choose delivery system and valve size based on prepared conduit based on prepared landing zone of conduit or BPV inside diameter and intended final implant size. Valve performance for both sizes is comparable, per bench testing data.1