Item number | Description | Units per case |
---|---|---|
SCD7A13 | Sonicision™ 7 13 cm curved jaw cordless ultrasonic dissector | 6 |
SCD7A26 | Sonicision™ 7 26 cm curved jaw cordless ultrasonic dissector | 6 |
SCD7A39 | Sonicision™ 7 39 cm curved jaw cordless ultrasonic dissector | 6 |
SCD7A48 | Sonicision™ 7 48 cm curved jaw cordless ultrasonic dissector | 6 |
CBCA | Sonicision™ battery charger | 1 |
SCSTA | Sonicision™ sterilization tray | 1 |
SCBA | Sonicision™ battery, reusable 200x | 1 |
SCBIGA | Sonicision™ battery insertion guide | 2 |
SCG7AA/AB | Sonicision™ 7 generator reusable 150x | 1 |
Ultrasonic dissection products
Sonicision™ 7 curved jaw cordless ultrasonic dissection device
<p>The Sonicision™ 7 curved jaw ultrasonic dissector is a cordless device capable of coagulating and dissecting vessels.</p>
Features
The tapered jaw design of the Sonicision™ 7 curved jaw device — designed for access and visibility
The tapered jaw design of the Sonicision™ 7 curved jaw device provides the access and visibility you need to advance care. Get precise access to tissue planes†,3 and access in tight spaces.‡,3 Visualize target structures‡,3 and the tips of the device throughout your procedures.‡,3 Discover its ability to follow curved anatomical structures.§,3
Next-generation design meets everyday convenience
With the Sonicision™ 7 curved jaw device, you’ll get a generator and battery that are reliable and efficient before, during, and after your procedures.
A reusable generator enables:
- Use for 150 procedures before replacement4
- Streamlined cleaning and sterilization because it’s autowashable and autoclavable
A reusable nonsterile battery pack provides:
- 88% greater capacity††,5 to instill confidence of consistent power throughout long procedures
- 200 procedural uses6,7 — twice the number of earlier devices††
An intuitive, easy-to-use‡‡,3 battery charger that:
- Makes it easy to interpret battery charge status‡‡,3 and battery end-of-life indications§§,3
- Enables efficient battery usage management‡‡,3
The culmination of innovation
Every step matters on the journey toward clinical innovation. That’s why we gauge each piece of our cordless ultrasonic dissection system through that lens — and design meaningful solutions to your most pressing needs.
Ordering information
Resources
Related products
Similar products
TM* Third-party brands are trademarks of their respective owners.
† 23 out of 27 surgeons surveyed after use agreed.
‡ 25 out of 27 surgeons surveyed after use agreed.
§ 29 out of 33 surgeons surveyed after use agreed.
◊ 24 out of 29 (82%) nurses surveyed after use answered extremely easy (59%) or easy (24%).
¶ 21 out of 27 surgeons surveyed after use agreed.
# 33 out of 33 surgeons surveyed after use agreed.
∆ 14 out of 14 (100%) nurses surveyed after use agreed.
∞ 30 out of 33 surgeons surveyed after use agreed.
†† Compared to the first-generation Sonicision™ system.
‡‡ 28 out of 28 (100%) nurses surveyed after use agreed.
§§ 27 out of 28 (96%) nurses surveyed after use agreed.
◊◊ In a head-to-head comparison with the Harmonic Ace™* +7 device, seven of eight surgeons surveyed after use said the dual-mode activation button of the Sonicision™ 7 device was more intuitive to use than the activation buttons for the Harmonic Ace™* +7 device.
- Based on internal test report RE00329878 rev A, Marketing evaluation of surgeon experience using the Sonicision™ 7 curved jaw cordless ultrasonic dissector. April 14–15 and 20-22, 2021.
- Based on internal test report R0042752 rev A, Marketing evaluation of surgeon experience using the Sonicision™ curved jaw cordless ultrasonic dissector. February 13–17, February 28, March 3, May 16, 2017.
- Based on internal test report R0049393 rev A, Operating room staff marketing evaluation of the Sonicision™ curved jaw cordless ultrasonic dissector. December 1, 6–7, 2016.
- Based on internal test report RE00108733, rev A, Reusable life test verification report (SCGAA-TA9). August 24, 2017.
- Based on internal test memo RE00153542, rev B, Battery capacity comparison between SCB and SCBA. May 17, 2018.
- Based on internal test report R0042707, rev A, Reusable life test verification report for the SCBA reusable battery pack. April 26, 2017.
- Based on internal test report RE00113195, rev A, Reusable life test verification report for the SCBA reusable battery pack — Oxivir. September 13, 2017.