Explore the clinical data supporting the Sphere-9™ catheter

Backed by over 100 publications1 and data from the first randomized controlled trial of pulsed field ablation (PFA) for persistent AF, the dual-energy Sphere-9™ radiofrequency (RF) and PFA catheter demonstrates proven safety, effectiveness, and procedural predictability.




SPHERE Per-AF Pivotal Trial2

A global, multicenter, randomized controlled trial comparing the dual-energy Sphere-9™ catheter with THERMOCOOL SMARTTOUCH™* SF catheter (RF control).

Proven safety and effectiveness with superior efficiency compared to the RF control (p < 0.0001):

  • 1.4% primary safety event rate
  • 74% primary effectiveness. 80% effectiveness for operators with > 10 cases (n = 75)4
  • 25+ minutes saved per procedure
  • 97% of cases completed with one catheter to map, ablate, and validate


Linear ablation analysis based on SPHERE Per-AF trial data6

PVI + additional linear ablation with the Sphere-9™ catheter resulted in numerically higher long-term effectiveness compared to patients treated using a similar ablation strategy with the RF control (75% versus 68%, p = 0.21; N = 204 and N = 124, respectively).‡

Efficient lesion delivery:

  • PVI: 24.5 minutes | 75.4 applications (N = 212)
  • LA posterior wall: 4.1 minutes | 16.2 applications (n = 203)
  • CTI line: 3.5 minutes | 10.4 applications (n = 117)
  • Mitral isthmus line: 5.6 minutes | 24.1 applications (n = 76)



‡ PVI + additional linear ablation includes at least one adjunctive ablation lesion set of the following: left atrial roof and posterior wall, mitral line, cavotricuspid isthmus (CTI) line.



Lab efficiency and health economics

Analyses based on SPHERE Per-AF trial data


Predictable procedure times and reduced overtime†,5

  • 45% more days with time for an additional nonablation case
  • 10-times reduction in cumulative overtime hours

Supports same-day discharge7

  • 55% increase in days supporting same-day discharge of the third ablation patient per day
  • No significant difference in safety outcomes versus the RF control (p = 0.53)

Additional days with third case same-day discharge modeled over 1,000 lab days†,5


Low- to no-fluoroscopy exposure8

  • 0 primary safety events in zero-fluoro cases
  • Conventional-fluoro users achieved lower fluoroscopy times with the Sphere-9™ catheter versus the RF control.


† Based on a discrete event simulation of 1,000 lab days using the SPHERE Per-AF trial data. These are not endpoints from the SPHERE Per-AF study but rather hypothetical modeling based on the data generated from the SPHERE Per-AF study.


Matched-adjusted indirect comparison: SPHERE Per-AF versus ADVANTAGE AF Phase I9

Sphere-9™ catheter versus FARAWAVE™* PFA catheter for the treatment of patients with persistent AF using indirect treatment comparison methods

Indirect comparisons are not a substitute for head-to-head trials. Indirect comparisons have potential bias from unmeasured confounding factors, reduced statistical power, and imperfect matching of treatment effect modifiers.


Higher probability of success§


77.4%

adjusted 12-month freedom from atrial arrhythmias in matched cohort of patients (Sphere-9™ catheter; n = 205)

vs.

63.5%

12-month freedom from atrial arrhythmias (FARAPULSE™* PFA system; n = 260; p = 0.003)


Even when adjusted
for differences in adjunctive ablation, results did not significantly change.◊



Dual-energy versatility in practice


One Sphere-9™ catheter used in > 97% of SPHERE Per-AF procedures (n = 206/212)2


Up to three catheters used in ADVANTAGE AF Phase I cases

  • Additional RF catheter used for CTI line ablation in 19% of patients (n = 50/260)
  • Supplementary high-density mapping catheter usage not reported. 3D mapping was used in 75% of cases (n = 195/260).


Comparable safety and efficiency


1.8%

adjusted major adverse event rate (Sphere-9™ catheter; n = 205)

vs.

2.3%

adjusted major adverse event rate (FARAWAVE™* PFA catheter; n = 260; p = 0.72)

Similar skin-to-skin procedure times despite more complex lesion sets performed with the Sphere-9™ catheter (p = 0.41)



§ OR 0.51 (95% CI:0.32–0.80), p = 0.003.

◊ MAIC-adjusted results for the sensitivity analysis performed to account for differences in adjunctive lesion sets: OR 0.44 (95% CI: 0.23–0.86), p = 0.017.




¶ Independent analysis from a single U.S. health system (three hospitals).


Independent experience with the Sphere-9™ catheter from a high-volume U.S. health system

Streamline workflows and reduce variability; see how the Sphere-9™ catheter offers improved economic value compared to over-the-wire (OTW) PFA.10

  • Offsets incremental costs through added procedural volume
  • $658 savings for PVI+ procedures Sphere-9™ catheter versus OTW PFA
  • Delivers capability to treat more patients with current lab and personnel resources


Lesion characteristics and durability


Lesion dimensions

Create lesions in less time11,12 with 10-times-larger effective surface area than standard irrigated ablation catheters.12

  • 5 seconds — radiofrequency (temperature controlled)
  • 4 seconds — pulsed field (unipolar, biphasic)



Lesion durability3

Remapping of patients treated with radiofrequency and the PULSE3 optimized waveform at 96 ± 43 days demonstrated durability in:

  • 90% per patient PVI durability (n = 31)
  • 97% per pulmonary vein durability (n = 124)
  • 91% linear ablation durability (n = 91)#
  • 100% LA roof line durability (n = 30)Δ

# All linear ablation target include left atrial roof line, mitral isthmus, and cavotricuspid isthmus.

Δ PFA was predominately used for LA roof line ablation, whereas other targets were ablated with various combinations of RF and PF energy.



Ongoing research


Affera Global Registry

Prospective, global, multicenter, observational post-market registry. The purpose of this study is to describe clinical performance and safety data in a broad patient population treated with the Affera™ platform.


Conquer-AF for Redo Ablation

Prospective, multicenter, interventional, nonrandomized clinical study. The safety and effectiveness of the Sphere-9™ catheter and Affera™ mapping and ablation system in patients undergoing redo ablation for symptomatic recurrent paroxysmal or persistent AF following a single ablation procedure.


SPHERE Per-AF Post-Approval Study

Prospective, multicenter, nonrandomized, observational trial. Subjects will be treated with the Sphere-9™ catheter and Affera™ mapping and ablation system and followed through 36 months to evaluate the long-term effectiveness and safety of the Sphere-9™ catheter and Affera™ system in a post-approval setting for the treatment of drug refractory, recurrent, symptomatic, persistent AF.


Sphere-9 VT Early Feasibility Study

Prospective, multicenter, nonrandomized, unblinded feasibility study. Adult subjects with recurrent, sustained, scar-related monomorphic ventricular tachycardia will be enrolled and treated with the Sphere-9™ catheter and Affera™ mapping and ablation system.


Sphere VT Pivotal Study

Prospective, multicenter, single-arm, unblinded pivotal clinical study. Adult subjects with recurrent, sustained, monomorphic ventricular tachycardia due to prior myocardial infarction will be enrolled and treated with the Sphere-9™ catheter and Affera™ system.