You just clicked a link to go to another website. If you continue, you will leave this site and go to a site run by someone else.
Medtronic does not review or control the content on the other website, and we are not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site are not approved in the Indian Subcontinent.
Any and all information provided is intended for general overview. Viewers taking any decision based on the information provided herein are requested to seek professional advice.
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
The content of this webpage is exclusively reserved for registered medical practitioners.
Click “OK” to confirm you are a registered medical practitioner.
Transcatheter aortic valve implantation (TAVI)
Delivering on ease of use through a more predictable and streamlined procedural experience.
Cusp Overlap Technique for TAVR Video - (02:02)
Watch this educational video summarizing the key points of the Evolut TAVR cusp overlap technique.
More information (see more)
Less information (see less)
Facilitate implant depth accuracy
The cusp overlap view isolates the noncoronary cusp and elongates the left ventricular outflow tract, providing a greater visual separation between the basal annular plane and the conduction system, and an accurate, patient-specific anatomical view to assess and achieve target implant depth.1
Predictable valve deployment
Slow deployment starting from a supra-annular position allows the valve to descend to its target position, providing users with control over valve deployment and requiring minimal catheter manipulation, which minimizes the risk of interaction with the conduction system.
The cusp overlap technique with an optimized care pathway continues to show dependable clinical outcomes.*
Accuracy when it matters most
Devices used: 91.5% Evolut™ PRO+/8.0% Evolut™ PRO.
* This is an interim analysis of 400 main cohort patients. At the conclusion of the study, more than 650 patients will have been evaluated.
Accurate depth assessment at the NCC, facilitated with the cusp overlap technique, has resulted in single-digit pacemaker rates in several single-center and multicenter clinical studies.
Excludes patients with baseline implantable cardioverter defibrillator or pacemaker.
†Discharge rates.
TAVI risks may include, but are not limited to, death, stroke, damage to the arteries, bleeding, and need for permanent pacemaker.
Explore the Evolut TAVI implant procedure on Medtronic Academy.
Find training modules, live cases, webinars, and more at your fingertips.
Grubb JK, Gada H, Mittal S, et al. Clinical Impact of Standardized TAVR Technique and Care Pathway: Insights from the Optimize PRO Study. JACC Cardiovasc Interv. March 13, 2023;16(5):558–570.
Gada H. TAVR in Low Risk Patients. Presented at TVT 2019.
Gada H, et al. Reduction of Rates of Permanent Pacemaker Implantation With 34-MM Evolut™ R Using Cusp Overlap Technique. Presented at TCT Connect 2020.
Gada H, et al. Reproducibility of Cusp Overlap Technique to Reduce Permanent Pacemaker Implantation With Evolut™: The Latin American Experience. Presented at TCT Connect 2020.
Pisaniello AD, Makki HBE, Jahangeer S, Daniels MJ, Hasan R, Fraser DGW. Low Rates of Permanent Pacing Are Observed Following Self-Expanding Transcatheter Aortic Valve Replacement Using an Annular Plane Projection for Deployment. Circ Cardiovascular Interv. January 2021;14(1):e009258.
Mendiz OA, Noč M, Fava CM, et al. Impact of Cusp-Overlap View for TAVR with Self-Expandable Valves on 30 Day Conduction Disturbances. J Interv Cardiol. April 28, 2021;2021:9991528.