Evolut™ FX+ TAVR System

TAVR without compromise

Design goals

Access

1. Waist: The Evolut™ FX+ TAV is designed with three windows that are 4 times larger to enable lifetime management solutions such as coronary access.1

Without compromise

2. Outflow: The Evolut™ FX+ TAV is designed with the same structural strength at the outflow as the Evolut™ FX valve.2

3. Inflow: The Evolut™ FX+ TAV is designed with the same radial force at the inflow as the Evolut™ FX valve.2

Built on the original CoreValve™ platform, Evolut™ FX+ is engineered with specific design elements to promote sustained valve performance with consistently large effective orifice area (EOAs) and low gradients over time. Evolut™ FX+ also uses the same Evolut™ FX delivery system designed for precision, flexibility, and control.

Blue outline of Evolut™ FX+ TAV with green highlights and callouts encircled in blue

Commissure alignment 

Commissural alignment facilitates future coronary access.3

Tang, et al., found the commissural alignment technique allows for more accurate placement and orienting the hat marker at the outer core during deployment reduces incidence of severe coronary overlap.4

Procedural vision

Using the valve radiopaque markers sustained from the Evolut™ FX system features, and following Evolut™ procedural technique, commissure alignment can be achieved.5

The Evolut™ FX+ windows are predicted to be aligned to the coronary ostias when following commissure alignment techniques.1

Evolut™ FX+ transcatheter aortic valve and delivery catheter with green highlighted areas

Post-TAVR coronary access

Coronary access is feasible through features of the Evolut FX platform.5 These features, such as valve radiopaque markers, are continued in the Evolut FX+ TAV design.

Procedural considerations

Learn more about post-TAVR percutaneous coronary intervention (PCI) best practices.

Illustration of the Evolut™ FX+ valve placement, highlighting coronary access

Resources

Manuals and technical guides

Related pages

Explore our other procedural guidance and outcomes you can expect from the Evolut™ platform.

Evolut™ 29 mm transcatheter aortic valve within a circular outline

Durability starts with design

Explore our design
Evolut™ FX transcatheter aortic valve being deployed using the Evolut™ TAVR/TAVI implant procedure

Evolut™ TAVR implant procedure

Explore the technique
Top-down view of the Evolut™ transcatheter aortic valve within a circular outline

Comprehensive clinical evidence

Explore the data

† Performance as compared to Evolut™ PRO+ and FX system in bench testing. Bench testing may not be indicative of clinical performance.

 1. Medtronic computational data model on file compared to the Evolut platform. Bench top computational model may not be indicative of clinical performance. Evolut FX+ Test Report: DO1106198 Rev. A.

 2. Performance as compared to Evolut PRO+ and FX system in bench testing. Bench testing may not be indicative of clinical performance. Medtronic data on file. Evolut FX+ Test Reports: D01073856, D01095344, D01084996.

3. Tarantini G, Fovino LN, Scotti A, et al. Coronary access after transcatheter aortic valve replacement with commissural alignment: The ALIGN-ACCESS Study. Circ Cardiovasc Interv. 2022;15(2):e011045. doi: 10.1161/CIRCINTERVENTIONS.121.011045.

4. Tang GHL, Sengupta A, Alexis SL, et al. Conventional versus modified delivery system technique in commissural alignment from the Evolut low-risk CT substudy. Catheter Cardiovasc Interv. 2022;99(3):924-931. doi: 10.1002/ccd.29973.

5. Attizzani G, Gabasha S, Filby S. TCT-248 Assessment of coronary cannulation, commissure and coronary alignment post-TAVR with the new supra-annular, self-expanding Evolut™ FX system. J Am Coll Cardiol. 2023;82(17):B97. DOI:10.1016/j.jacc.2023.09.255