Healthcare Professionals

Admiral Xtreme PTA Balloon Catheter

Percutaneous Transluminal Angioplasty

Overview

Treat longer PAD lesions above the knee with Admiral Xtreme™ PTA balloon catheter. Offered also in 250 and 300 mm lengths, with 0.035" guidewire compatibility, featuring large inflation lumen for rapid inflation and deflation.

Indications

The Admiral Xtreme is indicated for percutaneous transluminal angioplasty (PTA) in patients with obstructive diesease of peripheral arteries.

Contraindications

The Admiral™ Xtreme PTA catheter is contraindicated for the use in coronary arteries and supra-aortic vessels.It is also contraindicated when unable to cross the target lesion with a guide wire.

Product Details

Long Balloon Lengths

  • 250 and 300 mm balloon lengths are available for single dilatation of long lesions.
  • Proprietary technology prevents banana-shaped balloon.

Coaxial Dual-Lumen Shaft Design

  • Strong pushability and kink resistance are combined with flexibility.
  • Offers support for contralateral maneuvers. 
  • Large inflation lumen enable fast inflation and deflation.

Low Balloon Profile

  • Shows good refolding behavior. 
  • Cross lesions with confidence.

Hydrophilic Coating

  • Facilitates crossing.

Flexitec Xtreme Balloon Material

  • Balloon wall thickness is reduced.
  • Flexitec™ offers resistance against scratching.
  • Provides high rated burst pressure.

Manuals and Technical Guides

Instructions for Use Manual
Find this technical manual in the Medtronic Manual  Library, in the product labeling supplied with each device, or by calling Medtronic at  +1 763-526-7890. 

MODEL SPECIFICATIONS1

TECHNICAL SPECIFICATIONS

 
Type Specification
Catheter Design Over the wire (OTW)
Balloon Material Flexitec™ Xtreme
Balloon Coating Hydrophilic
Balloon Marker 2 swaged (zero profile) Platinum Iridium
Usable Shaft Lengths 80, 130 cm
Shaft Diameter 5 F - 6 F
Maximum Guidewire Compatibility 0.035"

ORDERING INFORMATION

Reference Number
Usable Length
80 cm
Reference Number
Usable Length
130 cm
Balloon Diameter
(mm)
Balloon Length
(mm)
Recommended
Introducer Sheath
(F)
RBP2
(atm)
SBI 030 020 080 SBI 030 020 130 3 20 5 18
SBI 030 040 080 SBI 030 040 130 3 40 5 18
SBI 030 080 080 SBI 030 080 130 3 80 5 18
SBI 030 120 080 SBI 030 120 130 3 120 5 18
SBI 040 020 080 SBI 040 020 130 4 20 5 18
SBI 040 040 080 SBI 040 040 130 4 40 5 18
SBI 040 060 080 SBI 040 060 130 4 60 5 18
SBI 040 080 080 SBI 040 080 130 4 80 5 18
SBI 040 120 080 SBI 040 120 130 4 120 5 18
SBI 040 150 080 SBI 040 150 130 4 150 5 14
SBI 040 200 080 SBI 040 200 130 4 200 5 14
SBI 040 250 080 SBI 040 250 130 4 250 5 14
SBI 040 300 080 SBI 040 300 130 4 300 5 14
SBI 050 020 080 SBI 050 020 130 5 20 5 17
SBI 050 040 080 SBI 050 040 130 5 40 5 17
SBI 050 060 080 SBI 050 060 130 5 60 5 17
SBI 050 080 080 SBI 050 080 130 5 80 5 15
SBI 050 120 080 SBI 050 120 130 5 120 5 15
SBI 050 150 080 SBI 050 150 130 5 150 5 14
SBI 050 200 080 SBI 050 200 130 5 200 5 14
SBI 050 250 080 SBI 050 250 130 5 250 5 14
SBI 050 300 080 SBI 050 300 130 5 300 6 14
SBI 060 020 080 SBI 060 020 130 6 20 5 17
SBI 060 040 080 SBI 060 040 130 6 40 5 17
SBI 060 060 080 SBI 060 060 130 6 60 5 17
SBI 060 080 080 SBI 060 080 130 6 80 5 15
SBI 060 120 080 SBI 060 120 130 6 120 5 15
SBI 060 150 080 SBI 060 150 130 6 150 5 12
SBI 060 200 080 SBI 060 200 130 6 200 6 12
SBI 060 250 080 SBI 060 250 130 6 250 6 12
SBI 060 300 080 SBI 060 300 130 6 300 6 12
SBI 070 020 080 SBI 070 020 130 7 20 5 16
SBI 070 040 080 SBI 070 040 130  7 40 5 16
SBI 070 060 080 SBI 070 060 130  7 60 5 14
SBI 070 080 080 SBI 070 080 130  7 80 5 14
SBI 070 120 080 SBI 070 120 130  7 120 6 12
SBI 070 150 080 SBI 070 150 130  7 150 6 12
SBI 070 200 080 SBI 070 200 130  7 200 6 12
SBI 070 250 080 SBI 070 250 130  7 250 6 12
SBI 080 020 080 SBI 080 020 130  8 20 6 14
SBI 080 040 080 SBI 080 040 130  8 40 6 14
SBI 080 060 080 SBI 080 060 130  8 60 6 11
SBI 080 080 080 SBI 080 080 130  8 80 6 11
SBI 090 020 080 SBI 090 020 130  9 20 6 14
SBI 090 040 080 SBI 090 040 130  9 40 6 14
SBI 090 060 080 SBI 090 060 130  9 60 6 11
SBI 090 080 080 SBI 090 080 130  9 80 6 11
SBI 100 020 080 SBI 100 020 130  10 20 6 11
SBI 100 040 080 SBI 100 040 130   10 40 6 11
SBI 120 020 080 SBI 120 020 130   12 20 7 11
SBI 120 040 080 SBI 120 040 130   12 40 7 11

See product catalog for complete, detailed product information.

1

Bench Test Data on File at Medtronic, Inc. Test data not indicative of clinical performance.