  • 90, 130, 150, 180 cm shaft lengths with 0.014" and 0.018" compatibility allow for more access options.
  • Improved rewrap technology enables multiple inflations.
  • Fast deflation may contribute to shorter procedure times.
  • Low-compliant balloon material addresses various lesions.
  • Offers complementary sizes to Pacific™ Xtreme.*

Excellent Crossability to Improve Lesion Crossing

  • Hydrophilic coating on shaft contributes to crossability.
  • Low profile enables high crossability.

Manuals and Technical Guides

Instructions for Use
Find this technical manual in the product labeling supplied with each device or by calling technical support for cardiovascular services: +1 763-526-7890.

Model Specifications

Type Specification
Catheter Design Over the Wire (OTW), Coaxial Shaft
Balloon Material Proprietary
Balloon Coating Hydrophilic
Balloon Marker 2 Swaged, Platinum Iridium
Usable Shaft Lengths 90, 130, 150, 180 cm
Shaft Diameter 4 F
Maximum Guidewire
Compatibility
0.018"
Reference Number
Catheter Length
90 cm
Reference Number
Catheter Length
130 cm
Reference Number
Catheter Length
150 cm
Reference Number
Catheter Length
180 cm
Balloon
Diameter
(mm)
Balloon
Length
(mm)
Minimum Sheath
Inner Diameter
(F)
Nominal
Pressure
(atm) 
RBP
(atm)
PCP 020 020 090 PCP 020 020 130 PCP 020 020 150 PCP 020 020 180 2.00 20 4 8 22
PCP 020 040 090 PCP 020 040 130 PCP 020 040 150 PCP 020 040 180 2.00 40 4 8 22
PCP 020 060 090 PCP 020 060 130 PCP 020 060 150 PCP 020 060 180 2.00 60 4 8 22
PCP 020 080 090 PCP 020 080 130 PCP 020 080 150 PCP 020 080 180 2.00 80 4 8 22
PCP 020 120 090 PCP 020 120 130 PCP 020 120 150 PCP 020 120 180 2.00 120 4 8 22
PCP 020 150 090 PCP 020 150 130 PCP 020 150 150 PCP 020 150 180 2.00 150 4 8 22
PCP 025 020 090 PCP 025 020 130 PCP 025 020 150 PCP 025 020 180 2.50 20 4 8 16
PCP 025 040 090 PCP 025 040 130 PCP 025 040 150 PCP 025 040 180 2.50 40 4 8 16
PCP 025 060 090 PCP 025 060 130 PCP 025 060 150 PCP 025 060 180 2.50 60 4 8 16
PCP 025 080 090 PCP 025 080 130 PCP 025 080 150 PCP 025 080 180 2.50 80 4 8 16
PCP 025 120 090 PCP 025 120 130 PCP 025 120 150 PCP 025 120 180 2.50 120 4 8 16
PCP 025 150 090 PCP 025 150 130 PCP 025 150 150 PCP 025 150 180 2.50 150 4 8 16
PCP 030 020 090 PCP 030 020 130 PCP 030 020 150 PCP 030 020 180 3.00 20 4 8 16
PCP 030 040 090 PCP 030 040 130 PCP 030 040 150 PCP 030 040 180 3.00 40 4 8 16
PCP 030 060 090 PCP 030 060 130 PCP 030 060 150 PCP 030 060 180 3.00 60 4 8 16
PCP 030 080 090 PCP 030 080 130 PCP 030 080 150 PCP 030 080 180 3.00 80 4 8 16
PCP 030 120 090 PCP 030 120 130 PCP 030 120 150 PCP 030 120 180 3.00 120 4 8 16
PCP 030 150 090 PCP 030 150 130 PCP 030 150 150 PCP 030 150 180 3.00 150 4 8 16
PCP 035 020 090 PCP 035 020 130 PCP 035 020 150 PCP 035 020 180 3.50 20 4 8 16
PCP 035 040 090 PCP 035 040 130 PCP 035 040 150 PCP 035 040 180 3.50 40 4 8 16
PCP 035 060 090 PCP 035 060 130 PCP 035 060 150  PCP 035 060 180 3.50 60 4 8 16
PCP 035 080 090 PCP 035 080 130 PCP 035 080 150  PCP 035 080 180 3.50 80 4 8 16
PCP 035 120 090 PCP 035 120 130 PCP 035 120 150 PCP 035 120 180 3.50 120 4 8 16
PCP 035 150 090 PCP 035 150 130 PCP 035 150 150 PCP 035 150 180 3.50 150 4 8 16
PCP 040 020 090 PCP 040 020 130 PCP 040 020 150 PCP 040 020 180 4.00 20 4 8 14
PCP 040 040 090 PCP 040 040 130 PCP 040 040 150 PCP 040 040 180 4.00 40 4 8 14
PCP 040 060 090 PCP 040 060 130 PCP 040 060 150 PCP 040 060 180 4.00 60 4 8 14
PCP 040 080 090 PCP 040 080 130 PCP 040 080 150 PCP 040 080 180 4.00 80 4 8 14
PCP 070 120 090 PCP 040 120 130 PCP 040 120 150 PCP 040 120 180 4.00 120 4 8 14
PCP 050 020 090 PCP 050 020 130 N/A PCP 050 020 180 5.00 20 4 8 14
PCP 050 040 090 PCP 050 040 130 N/A PCP 050 040 180 5.00 40 4 8 14
PCP 050 060 090 PCP 050 060 130 N/A  PCP 050 060 180 5.00 60 4 8 14
PCP 050 080 090 PCP 050 080 130 N/A  PCP 050 080 180 5.00 80 4 8 14
PCP 050 120 090 PCP 050 120 130 N/A  PCP 050 120 180 5.00 120 4 8 14
PCP 060 020 090 PCP 060 020 130 N/A  PCP 060 020 180 6.00 20 4 8 14
PCP 060 040 090 PCP 060 040 130 N/A  PCP 060 040 180 6.00 40 4 8 14
PCP 060 060 090 PCP 060 060 130 N/A  PCP 060 060 180 6.00 60 4 8 14
PCP 060 080 090 PCP 060 080 130 N/A  PCP 060 080 180 6.00 80 4 8 14
PCP 060 120 090 PCP 060 120 130 N/A  PCP 060 120 180 6.00 120 4 8 14
PCP 070 020 090 PCP 070 020 130 N/A  PCP 070 020 180 7.00 20 4 8 12
PCP 070 040 090 PCP 070 040 130 N/A  PCP 070 040 180 7.00 40 4 8 12
PCP 070 060 090 PCP 070 060 130 N/A  PCP 070 060 180 7.00 60 4 8 12
PCP 070 080 090 PCP 070 080 130 N/A  PCP 070 080 180 7.00 80 5 8 12
PCP 070 120 090 PCP 070 120 130 N/A  PCP 070 120 180 7.00 120 5 8 12

 

See product catalog for complete, detailed product information.

*

Pacific Plus available in lengths from 20 mm to 150 mm (diameter 2.0 to 3.5 mm), Pacific Xtreme available in lengths from 150 mm to 300 mm (for diameter 4.0 mm to 6.0 mm, 7.0 mm up to 250 mm).

Bench Test Data on File at Medtronic, Inc. Test data not indicative of clinical performance.