Available Trended Patient Data Parameters |
---|
Patient Data Parameter |
Symbol |
---|
Dynamic compliance |
CDYN |
PAV-based lung compliance |
CPAV |
Static lung compliance |
CSTAT |
PAV-based Lung Elastance |
EPAV |
End expiratory flow |
EEF |
Peak expiratory flow rate |
PEF |
Peak spontaneous flow rate |
PSF |
Total respiratory rate |
fTOT |
I:E ratio |
I:E |
Negative inspiratory force |
NIF |
Oxygen percentage (monitored) |
O2% |
P100 |
P0.1 |
End expiratory pressure |
PEEP |
Intrinsic PEEP |
PEEPI |
PAV-based intrinsic PEEP |
PEEPI PAV |
Total PEEP |
PEEPTOT |
Mean circuit pressure |
PMEAN |
Peak circuit pressure |
PPEAK |
Plateau pressure |
PPL |
Spontaneous rapid shallow breathing index |
f/VT |
Dynamic resistance |
RDYN |
PAV-based patient resistance |
RPAV |
Static resistance |
RSTAT |
PAV-based total airway resistance |
RTOT |
Spontaneous inspiratory time |
TI SPONT |
Spontaneous inspiratory time ratio |
TI/TTOT |
Vital capacity |
VC |
Exhaled minute volume |
V̇E TOT |
Exhaled spontaneous minute volume |
V̇E SPONT |
Exhaled tidal volume |
VTE |
Exhaled spontaneous tidal volume |
VTE SPONT |
Exhaled mandatory tidal volume |
VTE MAND |
Inspired tidal volume |
VTI |
Work of breathing |
WOBTOT |
Percent leak |
%LEAK |
Inspiratory leak |
VLEAK |
Exhaled tidal volume per kg PBW |
VTE/PBW |
End inspiratory pressure |
PI END |
Inspired tidal volume per kg PBW |
VTI/PBW |
End T=tidal CO2 |
ETCO2 |
Compliance ratio |
C20/C |
Inspiratory time constant |
3TauI |
Missed triggers (during IE sync monitoring) |
TRIGM |
Estimated inspiratory volume during leak sync |
VTL |
Leak rate at PEEP |
LEAK |
Exhalation leak at PEEP during leak sync measured by the proximal flow sensor |
LEAKY |
Inspired tidal volume measured by the proximal flow sensor |
VTIY |
Inspired tidal volume measured by the proximal flow sensor per kg PBW |
VTIY/PBW |
Estimated inspiratory volume during leak sync per kg PBW |
VTL/PBW |
Exhaled tidal volume measured by the proximal flow sensor |
VTEY |
Exhaled tidal volume measured by the proximal flow sensor per kg PBW |
VTEY/PBW |
Exhaled spontaneous tidal volume measured by the proximal flow sensor |
VTE SPONTY |
Exhaled spontaneous minute volume measured by the proximal flow sensor |
V̇E SPONTY |
Exhaled mandatory tidal volume when the proximal flow sensor is enabled |
VTEY MAND |
Inspiratory tidal volume during leak sync measured by the proximal flow sensor |
VTLY |
Estimated inspiratory volume per kg PBW during leak sync measured by the proximal flow sensor |
VTLY/PBW |
Exhaled minute volume when the proximal flow sensor is enabled |
V̇E TOTY |