No Image Available

Peripheral embolization products

MVP™ micro vascular plug system

<p>The MVP™ micro vascular plug system is indicated to obstruct or reduce the rate of blood flow in the peripheral vasculature.</p>

Features

Delivery animation

Watch the MVP™ device occlude a vessel.

A single-device approach

Decorative element

 

The MVP™ device offers one-device approach with rapid occlusion.1,2 This reduces procedure time and radiation exposure.1,2

Decorative element

 

The MVP™ device can be delivered to super-selective vasculature due to its flexible delivery design through a microcatheter.2

Decorative element

 

The MVP™ device provides a smooth and controlled procedure.1 It brings a combination of carefully engineered design features.

Limited presence of metal means minimal CT artifacts†,2


MVP™ device

MVP™ micro vascular plug system shown via X-ray imaging

Coils

Coils shown via X-ray imaging

Microcatheter compatible

 

MVP™ microcatheter vascular plug is compatible with both microcatheter and diagnostic catheters.

  • MVP™-3 and MVP™-5: microcatheter and diagnostic catheter delivery
  • MVP™-7 and MVP™-9: diagnostic catheter delivery

 

Illustration of the MVP™ micro vascular plug system inside the blood vessel
Chart showing the four sizes of the MVP™ micro vascular plug system being compatible with micro and diagnostic catheters

Design features

  1. Distal radiopaque marker for fluoroscopic visualization
  2. PTFE cover creates rapid occlusion and prevents recanalization3
  3. Proximal radiopaque marker for fluoroscopic visualization
  4. Easy and reliable detachment system3
  5. Soft wire for smooth navigation3
  6. Fully resheathable and repositionable during deployment

 

Design features of the MVP™ micro vascular plug system with numbered callouts

Case studies

Human peripheral vascular system with navy blue squares over treatment areas

Showcase

A collection of cases for peripheral embolization solutions.

This interactive experience allows you to browse through the anatomy and review real case studies from experienced physicians. Get started and see the versatility of the MVP™ device.

Hemorrhage case

Watch this case overview of a patient with trauma to the spleen.


Ordering information

Microvascular Plug specifications

Item number Recommended vessel size (mm) Outer diameter unconstrained (mm) Length unconstrained (mm) Delivery wire length (cm)
MVP-3Q 1.5–3.0 5.3 12 180
MVP-5Q 3.0–5.0 6.5 12 180
MVP-7Q 5.0–7.0 9.2 16 165
MVP-9Q 7.0–9.0 13.0 18 165

 

Recommended microcatheter/catheter specifications

Item number

Min. inner diameter (in)

Min. outer diameter

Guidewire compatibility (in)

Max. length (cm)

MVP-3Q 0.021

2.4 F

0.014-0.018 153
MVP-5Q 0.027

2.8 F

0.021-0.025 153 
MVP-7Q 0.041 (4 Fr)

4 F

0.035-0.038

120
MVP-9Q 0.043 (5 Fr) 5 F 0.038 120

 

Manuals and technical guides

The technical manual includes indications, warnings, precautions, MRI information, and directions for use. Find it in the product labeling supplied with each device.

MRI Information

™The MVP™ Micro Vascular Plug was determined to be MR conditional. Non-clinical testing demonstrated that the MVP Micro Vascular Plug Device is MR conditional. A patient with this device can be scanned safely, immediately after placement under the following conditions:

  • Static magnetic field of 3 Tesla or less
  • Maximum spatial gradient magnetic field of 9,000 Gauss/cm or less
  • Maximum MR system reported, whole body averaged specific absorption rate (SAR) of 4 W/kg for 15 minutes of scanning (i.e., per pulse sequence)
  • First Level Controlled Operating Mode for the MR system

™* Third-party brands are trademarks of their respective owners.

† Images are property of Medtronic.

‡ Up to three times.

  1. Pellerin O, Maleux G, Déan C, Pernot S, Golzarian J, Sapoval M. Microvascular plug: a new embolic material for hepatic arterial skeletonization. Cardiovasc Intervent Radiol. December 2014;37(6):1597-1601.
  2. Park JJ, Park JM. Reduced Metal artifact on CT utilizing the Medtronic MVP. EVT. October 2017; 16(10):34-36.
  3. Test data on file at Medtronic, TR13-067 rev B / TR13-081 Rev A / TR12-054 REV A / TR14-061 Rev A / TR14-062 Rev A / TR14-065 Rev A. Bench test results may not be indicative of clinical performance.