Peripheral embolization products
MVP™ micro vascular plug system
<p>The MVP™ micro vascular plug system is indicated to obstruct or reduce the rate of blood flow in the peripheral vasculature.</p>
Features
Delivery animation
Watch the MVP™ device occlude a vessel.
A single-device approach
The MVP™ device offers one-device approach with rapid occlusion.1,2 This reduces procedure time and radiation exposure.1,2
The MVP™ device can be delivered to super-selective vasculature due to its flexible delivery design through a microcatheter.2
The MVP™ device provides a smooth and controlled procedure.1 It brings a combination of carefully engineered design features.
Limited presence of metal means minimal CT artifacts†,2
MVP™ device
Coils
Microcatheter compatible
MVP™ microcatheter vascular plug is compatible with both microcatheter and diagnostic catheters.
- MVP™-3 and MVP™-5: microcatheter and diagnostic catheter delivery
- MVP™-7 and MVP™-9: diagnostic catheter delivery
Design features
- Distal radiopaque marker for fluoroscopic visualization
- PTFE cover creates rapid occlusion and prevents recanalization3
- Proximal radiopaque marker for fluoroscopic visualization
- Easy and reliable detachment system3
- Soft wire for smooth navigation3
- Fully resheathable and repositionable during deployment‡
Case studies
Showcase
A collection of cases for peripheral embolization solutions.
This interactive experience allows you to browse through the anatomy and review real case studies from experienced physicians. Get started and see the versatility of the MVP™ device.
Hemorrhage case
Watch this case overview of a patient with trauma to the spleen.
Ordering information
| Item number | Recommended vessel size (mm) | Outer diameter unconstrained (mm) | Length unconstrained (mm) | Delivery wire length (cm) |
|---|---|---|---|---|
| MVP-3Q | 1.5–3.0 | 5.3 | 12 | 180 |
| MVP-5Q | 3.0–5.0 | 6.5 | 12 | 180 |
| MVP-7Q | 5.0–7.0 | 9.2 | 16 | 165 |
| MVP-9Q | 7.0–9.0 | 13.0 | 18 | 165 |
Recommended microcatheter/catheter specifications
| Item number | Min. inner diameter (in) |
Min. outer diameter |
Guidewire compatibility (in) |
Max. length (cm) |
|---|---|---|---|---|
| MVP-3Q | 0.021 | 2.4 F |
0.014-0.018 | 153 |
| MVP-5Q | 0.027 | 2.8 F |
0.021-0.025 | 153 |
| MVP-7Q | 0.041 (4 Fr) | 4 F |
0.035-0.038 |
120 |
| MVP-9Q | 0.043 (5 Fr) | 5 F | 0.038 | 120 |
Manuals and technical guides
The technical manual includes indications, warnings, precautions, MRI information, and directions for use. Find it in the product labeling supplied with each device.
MRI Information
™The MVP™ Micro Vascular Plug was determined to be MR conditional. Non-clinical testing demonstrated that the MVP Micro Vascular Plug Device is MR conditional. A patient with this device can be scanned safely, immediately after placement under the following conditions:
- Static magnetic field of 3 Tesla or less
- Maximum spatial gradient magnetic field of 9,000 Gauss/cm or less
- Maximum MR system reported, whole body averaged specific absorption rate (SAR) of 4 W/kg for 15 minutes of scanning (i.e., per pulse sequence)
- First Level Controlled Operating Mode for the MR system
Related links
Related products
™* Third-party brands are trademarks of their respective owners.
† Images are property of Medtronic.
‡ Up to three times.
- Pellerin O, Maleux G, Déan C, Pernot S, Golzarian J, Sapoval M. Microvascular plug: a new embolic material for hepatic arterial skeletonization. Cardiovasc Intervent Radiol. December 2014;37(6):1597-1601.
- Park JJ, Park JM. Reduced Metal artifact on CT utilizing the Medtronic MVP. EVT. October 2017; 16(10):34-36.
- Test data on file at Medtronic, TR13-067 rev B / TR13-081 Rev A / TR12-054 REV A / TR14-061 Rev A / TR14-062 Rev A / TR14-065 Rev A. Bench test results may not be indicative of clinical performance.