No Image Available

Intrasaccular devices

Artisse™ intrasaccular device

<p>Artisse™ is a flex-to-fit intrasaccular device that conforms to the shape of the aneurysm.&nbsp;</p>

Features


Innovation

Advancing our legacy of haemorrhagic innovation: With advanced atraumatic open tip design, conformability, flared shape and proximal flow divider profile to remodel flow.1, 2, 3, 4, 5, 6, 7, 8, 9

  • Conformability: Unique construction and low stiffness modulus conforms to the aneurysm and neck.8, 9
  • Control: All sizes through an 021 microcatheter with low handling forces and highly rated control.7, 8, 9
  • Ease of use: Leverage conformability and multiple modalities of sizing* working together for a personalized fit for patients.3, 4, 8, 9, 10 INSPIRE-A demonstrated a 96.9% patient-level implant success rate with a mean cumulative fluoro time of 24.7 mins.11

Efficacy and Safety

Raising the bar with meaningful Raymond Roy class 1 outcomes. Achieving high complete occlusion rates and low adverse events, demonstrated by the INSPIRE-A real world multi-center registry.11


Artisse Detachment Device

Reliable detachment

Electrolytic detachment with audible and visual communicatins on detachment status.4

Ordering information

Artisse™ Intrasaccular Device

Item number Diameter (mm) Height (mm) Recommended Microcatherer (0.021")
ISF-045-030 4.5 3.0 Rebar-18
ISF-045-040 4.5 4.0 Rebar-18
ISF-050-030 5.0 3.0 Rebar-18
ISF-050-040 5.0 4.0 Rebar-18
ISF-055-030 5.5 3.0 Rebar-18
ISF-055-040 5.5 4.0 Rebar-18
ISF-055-050 5.5 5.0 Rebar-18
ISF-060-030 6.0 3.0 Rebar-18
ISF-060-040 6.0 4.0 Rebar-18
ISF-060-050 6.0 5.0 Rebar-18
ISF-065-030 6.5 3.0 Rebar-18
ISF-065-040 6.5 4.0 Rebar-18
ISF-065-050 6.5 5.0 Rebar-18
ISF-070-030 7.0 3.0 Rebar-18
ISF-070-040 7.0 4.0 Rebar-18
ISF-070-050 7.0 5.0 Rebar-18
ISF-075-040 7.5 4.0 Rebar-18
ISF-075-050 7.5 5.0 Rebar-18
ISF-080-040 8.0 4.0 Rebar-18
ISF-080-050 8.0 5.0 Rebar-18

Artisse™ Detachment Device

Item number Description
ISD-5-PK Artisse™ Detachment Device (5-pack)

*2-D sizing chart and 3D-Simulation

  1. Data on file D00662662 Artisse 2 Rabbit Vessel Pouch Aneurysm GLP Animal Study Design Validation Report. Testing performed with 14 rabbits with a preexisting surgically created elastase induced aneurysm. 06-Nov-2023
  2. Data on file D00360690 Artisse 2 Design Verification Implant Shape and Chronic Outward Force Report. 23-Nov-2020
  3. Data on file D00357033 Artisse 2 Intrasaccular Device Design Validation Report. 17-Nov-2020
  4. Data on File TR-NV12962 Artisse-021 System Design Validation Report. 19-Jul-2016
  5. Data on File M810805ADOC1 Artisse Implant Subassembly. 18-Sep-2023
  6. Data on File D00789514 Artisse 2 25% Compression Radial Force Design Verification Testing Report. 02-Sep-2022
  7. Competitive testing report, intrasaccular device competitive evaluation. Data on file D01177929 Rev A
  8. Data on File Artisse Intrasaccular Device Conformability and Control Physician Survey
  9. NeuroNews Physician Interview on Clinical Perspectives on Artisse. Advertorial May 2024, Issue 54
  10. Sim&Size v1.2 User manual
  11. Artisse INSPIRE-A, 12M Safety and Efficacy Data as presented by Prof Killer at LINNC Paris 2025. (Interim data. Enrollment and follow-up ongoing. This is not the final data set.)