Achieve™ mapping catheter
| Item number | Loop size (mm) | Electrode spacing (mm) |
|---|---|---|
| 990063-015 | 15 | 4.1 (0.161 in) |
| 990063-020 | 20 | 5.8 (0.228 in) |
Cryoablation catheters
<p>The Achieve™ mapping catheter enables the assessment of pulmonary vein isolation during cryoablation procedures.</p>
The Achieve™ mapping catheter allows for the assessment of pulmonary vein (PV) isolation during the cryoablation procedure. The catheter is deployed through the cryoballoon guide wire lumen, minimizing the number of catheter exchanges and allowing the procedure to be performed using a single transseptal puncture. The Achieve™ mapping catheter may also provide recording of real-time PV potentials during cryoablation with the cryoballoon.
The distal mapping section of the Achieve™ mapping catheter is a circular loop with eight evenly spaced electrodes for mapping electrical conduction between the left atrium and pulmonary veins. The catheter may also be used for cardiac stimulation during electrophysiology studies. The Achieve™ catheter features a cable with eight shielded electrocardiography (ECG) pins to connect into standard electrophysiology (EP) recording and pacing equipment.
| Size | |
|---|---|
| Catheter shaft size | 3.3 Fr, 1.1 mm (0.043 in) |
| Total length | 165 cm |
| Useable length | 146 cm |
| Loop | |
| Loop size | 15 mm (.591 in) or 20 mm (.787 in) |
| Number of electrodes | 8 |
| Electrode length | 1 mm (0.0394 in) |
| Electrode spacing | 4 mm (0.157 in) or 6 mm (0.236 in) |
| Compatibility | |
| Catheter compatibility | Minimum ID of 3.8 Fr, 1.3 mm (0.049 in) |
| Item number | Loop size (mm) | Electrode spacing (mm) |
|---|---|---|
| 990063-015 | 15 | 4.1 (0.161 in) |
| 990063-020 | 20 | 5.8 (0.228 in) |
The Achieve Advance™ is an intra-cardiac mapping and diagnostic catheter for cardiac ablation procedures for atrial fibrillation.
The Arctic Front Advance Pro™ enables pulmonary vein isolation (PVI) using an anatomical approach during atrial fibrillation (AF) catheter ablation procedures.
The Arctic Front Advance™ over-the-wire balloon catheter is designed to enable pulmonary vein isolation (PVI) during atrial fibrillation ablation procedures.
The Freezor™ cardiac cryoablation catheters are single-use catheters designed to ablate cardiac tissue by creating focal lesions.
We do not review or control the content of external sites and are not responsible for any interactions or transactions that may occur there. Any product availability and regulatory requirements on the destination site may differ depending on your location. When you continue, the terms of use and privacy statement of the external site will apply.
Product availability and regulatory requirements may differ depending on your location. The destination website is governed by the laws and regulations of the country in which it operates, which may be different from those in your country. When you continue, the terms of use and privacy statement of the destination Medtronic site will apply.