| Item number | Description | Shaft length (cm) | Units per box |
|---|---|---|---|
| LF1823 | LigaSure™ blunt tip laparoscopic sealer-divider with nano-coating | 23 | 6 |
| LF1837 | LigaSure™ blunt tip laparoscopic sealer-divider with nano-coating | 37 | 6 |
| LF1844 | LigaSure™ blunt tip laparoscopic sealer-divider with nano-coating | 44 | 6 |
Laparoscopic instruments
LigaSure™ blunt tip sealer-divider with nano-coating
<p>The LigaSure™ blunt-tip open and laparoscopic sealer-divider delivers vessel sealing- with nonstick nano-coating on the jaws.</p>
Features
Non-stick nano-coating
The LigaSure™ blunt tip device with nano-coating delivers fewer procedural interruptions:
- Reduced eschar buildup1
- Decreased instances of sticking2
- Reduce jaw cleanings − exchanges1
Multifunctional flexibility
With the LigaSure™ blunt tip device you get the benefits of:
- Straight rounded jaw for enhanced blunt dissection3
- An atraumatic grasper to securely grasp tissue4
- Cold scissors to leave the critical decision to cut in your hands
Multifunctional performance
The LigaSure™ blunt tip device delivers:
- Latching handle design for controlled sealing
- Bi-lateral jaws to better facilitate dissection through planes and creation of windows5
- Easy activation for stability and control when sealing vessels6
Available in three lengths to meet different procedural needs
- 23 cm
- 37 cm
- 44 cm
Specifications
| Physical characteristics | |
|---|---|
| General | Sterile, single use |
| Shaft diameter (mm) | 5 |
| Shaft rotation | 180 degrees |
| Jaw design | Blunt, double-action jaws with contoured tips |
| Seal plate length (mm) | 18.3 |
| Cut length (mm) | 16.8 |
| Foot switching | Yes |
| Generator compatibility | Valleylab™ FT10 energy platform, Valleylab™ LS10 generator |
Ordering information
Resources
Related products
Similar products
-
BiZact™ tonsillectomy deviceThe BiZact™ device is a bipolar tissue sealer and divider that is designed to solve the problems of tonsillectomy.
-
LigaSure™ Exact dissectorThe LigaSure™ Exact dissector is a surgical dissection device with nonstick nano-coated jaws.
-
LigaSure™ Maryland jaw sealer-divider with nano-coatingThe LigaSure™ Maryland jaw laparoscopic sealer-divider vessel sealing device includes a nonstick nano-coating technology.
-
LigaSure™ Maryland jaw thoracic sealer-divider with nano-coatingThe LigaSure™ Maryland jaw thoracic sealer-divider is a multifunctional nano-coated instrument designed for sealing pulmonary veins and arteries.
-
LigaSure™ XP Maryland jaw sealer-divider with nano-coatingThe LigaSure™ XP Maryland jaw device offers next-level vessel sealing technology − including latching handles and one-step sealing.
-
LigaSure™ curved jaw open sealer-dividerThe LigaSure™ curved jaw open sealer-divider is a vessel sealing device with a reusable metal clamp and a disposable attachment.
-
LigaSure™ retractable L-hook laparoscopic sealer-dividerThe LigaSure™ retractable L-hook laparoscopic sealer-divider combines the functionality of five laparoscopic devices into one versatile instrument.
-
LigaSure™ robotic-assisted surgery (RAS) Maryland jaw vessel sealer-dividerThe LigaSure™ RAS Maryland jaw vessel sealer-divider pairs with the Hugo™ RAS system as the first robotically driven LigaSure™ instrument.
TM* Third-party brands are trademarks of their respective owners.
† 11 of 11 surgeons agreed when compared to the predecessor device.
‡ Cleaning effectiveness assessed after each of two cleaning cycles.
§ Instances of tissue sticking to jaws measured over 110 seals per device.
◊ Eschar buildup assessed using optical imaging analysis after 20, 40, and 60 seal and divide cycles.
¶ Using a wet gauze cleaning fixture and optical imaging analysis. Cleaning effectiveness is assessed after each of two cleaning cycles.
- Based on internal test report RE00063136, Lig-42 report product claim LF18XX: benchtop testing conducted using porcine uterine tissue, a wet guaze cleaning fixture, and optical imaging analysis. Eschar buildup assessed using optical imaging analysis after 20, 40, and 60 seal and divide cycles. September 9, 2016.
- Based on internal test report RE00062678, Benchtop tissue sticking comparison of the Ethicon™* G2, Voyant™* 5 mm Fusion, LigaSure™ LF1637, and LigaSure™ LF1837 devices conducted on porcine uterine tissue using the ForceTriad™ energy platform. Instances of tissue sticking to jaws measured over 110 seals per device. October 5, 2016.
- Based on internal test report RE00063136, Lig-42 report product claim LF18XX: benchtop testing conducted using porcine uterine tissue, a wet guaze cleaning fixture, and optical imaging analysis. Cleaning effectiveness assessed after each of two cleaning cycles. September 9, 2016.
- Based on internal test report RE00056715-A, Design validation of LigaSure™ iterations gold LF18XX, blunt tip sealer-divider, nano-coated: independent surgeon feedback collected during Medtronic-sponsored lab; 11 of 11 surgeons agreed. August 16–17, 2016.
- Based on internal test report RE00074484, Gold II validation marketing report, Las Vegas and St. Louis: independent surgeon feedback collected during cadaver and porcine labs; 17 of 18 surgeons agreed. July 28–August 8, 2014.
- Based on internal test report RE00065374 Rev A, LF18XX product claims report for reprocessed jaws; 17 of 18 surgeons agreed. September 22, 2016, and September 29, 2016.