<p>The Liberant™ RX device is a 5 Fr aspiration catheter for thrombectomy procedures in arterial vessels.</p>


Indication: The Liberant™ RX aspiration catheter is indicated for the following: the removal/aspiration of embolic material (thrombus/debris) from vessels of the arterial system and to subselectively infuse/deliver diagnostic or therapeutic agents with or without vessel occlusion.


Product details


The Liberant™ RX device is a 5 Fr, durable,†,1 dual-lumen aspiration catheter for arterial vessels. It is intended for direct use with the Riptide™ aspiration pump.


  1. Hydrophilic coating for smooth advancement through difficult vessels1
  2. Preloaded, removable stylet to aid in kink resistance and catheter delivery
  3. Improved catheter tip
    • 23% larger aspiration lumen tip surface area
    • 15% greater suction force‡,1
    • Distal radiopaque marker
  4. Proximal markers at 90 and 100 cm indicate point at which aspiration catheter exits guide catheter
This is an image of the Liberant™ RX aspiration catheter features with numbered callouts for specific components.

Small outer diameter for better
trackability below the knee†,1

32%
improved trackability§,1

This is an image of the Liberant™ RX aspiration catheter.

Frequently asked questions

The Liberant™ RX aspiration catheter is indicated for the following: removal/aspiration of embolic material (thrombus/debris) from vessels of the arterial system and to subselectively infuse/deliver diagnostic or therapeutic agents with or without vessel occlusion.

The Liberant™ RX aspiration catheter is intended for direct use with the Riptide™ aspiration pump part of the Liberant™ thrombectomy system.

The Liberant™ RX aspiration catheter features an improved catheter tip with 23% larger aspiration lumen tip surface area, 15% greater suction force,‡,1 and 32% improved trackability.§,1


Ordering information

Item number Description  Size (Fr) Catheter shape
Working length (cm)
Catheter outer diameter (mm)
LMT-RX Liberant™ RX aspiration catheter 5 Straight 140 1.73

 

 

TM* Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.

† Based on rotations to fracture data with Liberant™ RX catheter compared CAT™* RX device.

‡ Based on bench data with Liberant™ RX catheter compared to CAT™* RX device.

§ Based on trackability bench data with Liberant™ RX catheter compared to CAT™* RX device.

  1. D01511656 Rev A. In-Vitro Marketing Testing Report - Liberant RX Aspiration Catheter and Penumbra Indigo CAT RX. Data on file at Medtronic. Bench testing may not be indicative of clinical performance.