Thrombectomy devices
Liberant™ RX aspiration catheter
<p>The Liberant™ RX device is a 5 Fr aspiration catheter for thrombectomy procedures in arterial vessels.</p>
Indication: The Liberant™ RX aspiration catheter is indicated for the following: the removal/aspiration of embolic material (thrombus/debris) from vessels of the arterial system and to subselectively infuse/deliver diagnostic or therapeutic agents with or without vessel occlusion.
Product details
The Liberant™ RX device is a 5 Fr, durable,†,1 dual-lumen aspiration catheter for arterial vessels. It is intended for direct use with the Riptide™ aspiration pump.
- Hydrophilic coating for smooth advancement through difficult vessels1
- Preloaded, removable stylet to aid in kink resistance and catheter delivery
- Improved catheter tip
- 23% larger aspiration lumen tip surface area‡
- 15% greater suction force‡,1
- Distal radiopaque marker
- Proximal markers at 90 and 100 cm indicate point at which aspiration catheter exits guide catheter
Small outer diameter for better
trackability below the knee†,1
32%
improved trackability§,1
Frequently asked questions
The Liberant™ RX aspiration catheter is indicated for the following: removal/aspiration of embolic material (thrombus/debris) from vessels of the arterial system and to subselectively infuse/deliver diagnostic or therapeutic agents with or without vessel occlusion.
The Liberant™ RX aspiration catheter is intended for direct use with the Riptide™ aspiration pump part of the Liberant™ thrombectomy system.
The Liberant™ RX aspiration catheter features an improved catheter tip with 23% larger aspiration lumen tip surface area,‡ 15% greater suction force,‡,1 and 32% improved trackability.§,1
Ordering information
| Item number | Description | Size (Fr) | Catheter shape |
Working length (cm) |
Catheter outer diameter (mm) |
|---|---|---|---|---|---|
| LMT-RX | Liberant™ RX aspiration catheter | 5 | Straight | 140 | 1.73 |
TM* Third-party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
† Based on rotations to fracture data with Liberant™ RX catheter compared CAT™* RX device.
‡ Based on bench data with Liberant™ RX catheter compared to CAT™* RX device.
§ Based on trackability bench data with Liberant™ RX catheter compared to CAT™* RX device.
- D01511656 Rev A. In-Vitro Marketing Testing Report - Liberant RX Aspiration Catheter and Penumbra Indigo CAT RX. Data on file at Medtronic. Bench testing may not be indicative of clinical performance.