Features

  • Has two sizes available, small and large, for both adult and pediatric use
  • May be placed at patient or equipment side
  • Lightweight, compact design reduces circuit weight
  • Low resistance to flow reduces work of breathing1
  • ISO standard 15 mm and 22 mm fitting connects to breathing circuit

Specifications

  Large – Barrierbac  Small – Barrierbac S Small, angled – Barrierbac S-A Small – Barrierbaby
Tidal volume 300–1500 mL 150–1200 mL 150–1200 mL 300–100 mL
Resistance to flow before use (ISO 9360-1) (ISO 23328-2)
5 L per minute 0.5 cmH20
15 L per minute 0.4 cmH20 0.4 cmH20 2.2 cmH20
30 L per minute 0.6 cmH2O 0.8 cmH2O 0.8 cmH2O
60 L per minute 1.4 cmH2O 2.0 cmH2O 1.9 cmH2O
90 L per minute 2.3 cmH2O 3.3 cmH2O 3.2 cmH2O
Filtration efficiency
NaCl (ISO 23328-1) 99.4% 98.2% 98.2% 93.6%
Bacterial Greater than or equal to 99.9999% Greater than or equal to 99.9999% Greater than or equal to 99.9999% Greater than or equal to 99.999%
Viral Greater than or equal to 99.999% Greater than or equal to 99.999% Greater than or equal to 99.999% Greater than or equal to 99.99%

Internal volume

 (ISO-9360-1)

(ISO 23328-1)

102 mL 39 mL 44 mL 11 mL
Weight 31.5 g 16 g 21 g 8 g

Ordering information

DAR™ electrostatic filters

Item number Size Patient end connection Machine end connection Units per box
350U5865 Large 22M/15F 22F 50
350U5879 Small 22M/15F 22F/15M 50
350S19006 Small with angled port 22M/15F 22F/15M 25

DAR™ electrostatic filters accessories

Item number Description Connection 1 Connection 2 Units per box
332U5115 DAR™ extension tube 15F 15M 25
332U5663 DAR™ extendible extension tube 15F 15M 25
610U5257 DAR™ double-swivel connector 22M/15F 15M 50
331U5661 DAR™ double-swivel connector, extendible 22M/15F 15M 25