Ventilator filters and HMEs
DAR™ HME
Ventilator filters and HMEs
DAR™ HME
The DAR™ HME minimizes heat and moisture loss from patient airways during anesthesia or respiratory care.
Description
DAR™ heat and moisture exchangers (HME) minimize heat and moisture loss from patient airways during anesthesia or respiratory care, assuring a proper climatization of inspired gases.
The DAR™ foam HME features an integrated extendable catheter mount for breathing circuits. The DAR™ adult-pediatric small HME includes a Luer lock fitting and a Luer lock cap for use during CO2 monitoring.
Features
- ISO standard 15 mm and 22 mm fittings
- Available with end tidal CO2 port, which offers convenient access to airway gases
- Available with integrated extendable connector to simplify setup
Specifications
Adult–pediatric small — Hygrolife II† | Adult–pediatric foam HME with integrated catheter mount — flexlife† | ||
---|---|---|---|
Tidal volume | 100–1000 mL | 200–1000 mL | |
Moisture loss (9360-1) | 8 mgH20/L at Vt 500 mL | 5 mgH20/L at Vt 500 mL | |
Resistance to flow before use (ISO 9360-1) (ISO 23328-2) | |||
30 L per minute | 1.0 cmH2O | 0.4 cmH2O | |
60 L per minute | 2.3 cmH2O | 1.1 cmH2O | |
90 L per minute | 3.8 cmH2O | 2.0 cmH2O | |
Internal volume (ISO 9360-1) (ISO 23328-2) |
29 mL | 76— 91 mL | |
Weight | 22 g | 12 g |
Ordering information
DAR™ HME filter accessories
Similar products
-
DAR™ electrostatic filter
The DAR™ electrostatic filter helps to protect patients, equipment, and hospital staff from cross-contamination.
-
DAR™ electrostatic filter HME
The DAR™ electrostatic filter HME helps protect against cross-contamination while minimizing heat and moisture loss from patient airways.
-
DAR™ mechanical filter
The DAR™ mechanical filter helps protect patients, equipment, and hospital staff from cross contamination.
-
DAR™ mechanical filter HME
The DAR™ mechanical filter HME helps protect against cross-contamination while minimizing heat and moisture loss from patient airways.
-
Puritan Bennett™ D-X800 expiratory filter
The Puritan Bennett™ D-X800 expiratory bacteria filter is disposable and designed for the Puritan Bennett™ 840 ventilator.
-
Puritan Bennett™ Re-X700 expiratory filter
The Puritan Bennett™ Re-X700 expiratory filter is a reusable filter designed for use with the Puritan Bennett™ 700 series ventilator.
-
Puritan Bennett™ Re-X800 expiratory bacterial filterThe Puritan Bennett™ Re-X800 expiratory bacterial filter is a reusable filter designed for use with the Puritan Bennett™ 840 ventilator.
-
Puritan Bennett™ expiratory filterThe Puritan Bennett™ expiratory filter is a disposable filtration solution for Puritan Bennett™ 700 series ventilators.
-
Puritan Bennett™ neonatal expiratory filtration system
The Puritan Bennett™ neonatal expiratory filtration system is a disposable neonatal filter designed for use with the Puritan Bennett™ 980 ventilator.
All technical information is sourced from various information for use (IFU) documents and clinical evaluation reports. Please reference the instructions for use (IFU) for a complete product details.
† Internal testing Mirandola (various 2005–2008). All technical information is sourced from information for use (IFU) documents PT00144742, PT00191236, PT00162624, and clinical evaluation report CER10055277. Please reference the IFU for complete product details.