| Item number | Minimum sheath size (Fr) | Inner diameter of the working channel |
|---|---|---|
| MOM0130068X5 | 8 | 0.069"/1.76mm |
| MOM0130069X6 | 9 | 0.083"/2.12mm |
Embolic protection devices
Mo.Ma™ Ultra proximal cerebral protection device
<p>The Mo.Ma™ Ultra proximal cerebral protection device contains and removes all sizes of debris during interventional procedures in the carotid arteries.</p>
Indications
Mo.Ma™ Ultra cerebral protection device is intended to be used during angioplasty and stenting of lesions located in the the Internal Carotid Artery (ICA) and/or lesions involving the carotid bifurcation. This device allows protection of the brain from cerebral embolism during the entire duration of the intervention, thus preventing severe and disabling complications. The system allows achieving cerebral protection before target lesion crossing, plus allowing debris removal by blood aspiration at any stage during the procedure.
Mo.Ma double-balloon
Mo.Ma Ultra is indicated to be used in patients eligible for carotid angioplasty and/or stenting with stenosis involving the the Internal Carotid Artery (ICA) and/or the carotid bifurcation and reference diameter of ECA from 3 to 6 mm and reference diameter of CCA from 5 to 13 mm.
Features
Proximal cerebral protection
- Antegrade flow from the common carotid artery (CCA) and retrograde flow from the external common carotid artery (ECA) are temporarily suspended by dual inflation establishing proximal cerebral protection.
Double-occlusion balloon system
Uses highly compliant, elastomeric balloons that provide atraumatic flow suspension and stability
Guide-catheter technology
Provides excellent trackability, support, and stability for ease of lesion crossing and accurate stent deployment
Working channel exit portal distal to CCA balloon
Provides lesion access and effective, efficient aspiration of debris†
Radiopaque markers
Markers are centrally located in each balloon for precise positioning and orientation
Optimal device selection
Allows for selection of preferred wires, stents, and balloons during intervention
High-capture efficiency
Facilitates the removal of all sizes of debris through aspiration‡
Animation: MoMa Ultra Proximal Cerebral Protection Device
Animation that demonstrates how to use the MoMa Ultra Proximal Cerebral Protection Device to contain and remove all sizes of debris that can dislodge during interventional procedures in the carotid arteries.MoMa, animation, Ultra Proximal Cerebral Protection Device, UC202003387, UC202003387EE
Manuals and Technical Guides
Instructions for Use
Find this technical manual in the product labeling supplied with each device.
Specifications
| Type |
Description |
|---|---|
| Balloon material | Compliant elastomeric rubber |
| Balloon marker distance§ | 6 cm |
| Balloon occlusion range§ | 5–13 mm diameter (CCA prox. balloon) 3–6 mm diameter (ECA dist. balloon) |
| Recommended guidewire | 0.035” (0.89 mm) |
Ordering information
Related links
† Data on file at Medtronic as per claims matrix UC202115163EN_Claims matrix Mo.Ma Ultra.
‡ See instructions for use for complete procedure requirements.