Portfolio of full-body MR Conditional† DBS systems
Unlimited scan time for both 1.5T and 3T scans below specified B1+rms limits
The only 3T and 1.5T MR Conditional† directional DBS systems
Percept™ PC and Percept™ RC batteries allow DBS therapy to remain on during an MRI scan
No restrictions on prone position for breast scans with Medtronic DBS systems1
Full-body MRI access
Only Medtronic offers DBS systems† that provide patients with the most diagnostic imaging options.1–3
Unlimited scan time for both 1.5T and 3T scans below specified B1+rms limits.
Your DBS patient may need an MRI
~10M
scans in the U.S. performed annually4 The only 3Tand 1.5T MR conditional for directional leads
77%
MRI scans ordered globally are not brain related.5 Medtronic offers greater freedom and scan access with 3T scans and best-in-class full system 1.5T MRI scan labeling1–3 for directional leads.
1 in 8
women will develop breast cancer6 No restrictions on prone position for breast scans with Medtronic DBS systems1
The Medtronic MRI advantage is clear
Medtronic offers DBS systems that provide patients with the diagnostic imaging care they need.†,1–3
Medtronic†,1–3
Boston Scientific2
Abbott3
Unlimited scan time for both 1.5T and 3T scans†,§,1
✔
✘
✘
Therapy on in bipolar while having a scan
✔
✘
✘
Offers both 3T and 1.5T MRI
✔
✘
✘
Best-in-class 1.5T for full systems with directional leads
✔
✘
✘
3T MRI beyond Normal Operating Mode RF power for both 4 contact and directional leads
✔
✘
✘
Capable of scans with the preferred MRI solution for many conditions - 3T MRI7
✔
✘
✘
MR Conditional neurostimulators
Comfort
Only Medtronic expanded MR Conditional† labeling for full body systems allow your patient to leave their DBS device on (in bipolar mode) to provide uninterrupted therapy.
We performed 14 years of rigorous MRI research and testing to demonstrate the safety of our devices for MRI, including over 700,00 specific cases‡,8 and 10 million simulated patient scans.
Filtered feedthrough technology mitigates radiofrequency (RF) energy from entering and damaging the device.
Minimal ferrous material reduces potential for unwanted device and lead movement caused by magnetic pull.
Protection diodes help prevent failure when exposed to electromagnetic interference.
† Medtronic DBS systems are MR Conditional. Refer to product labeling for full list of conditions. See Medtronic manuals library.
‡ Including patient size, position within the MRI machine, landmark location, deep brain target location, pulse generator location, and lead path.
§ Below specified B1+rms limits
MRI guidelines for Medtronic deep brain stimulation systems 37601, 37602, 37603, 37612, B35200, B35300 — M056974C001 Rev A. See Medtronic manuals library.