Descripción general

Seguro. Rápido. Eficiente.

El dispositivo de cierre de heridas V-Loc™ es una tecnología revolucionaria que elimina la necesidad de realizar nudos, de forma que puede cerrar incisiones hasta un 50 % más rápido sin comprometer la resistencia y la seguridad.([FOOTNOTE=Estudio temporal: Comparación del tiempo de cierre de heridas utilizando técnicas convencionales y suturas quirúrgicas sin nudos y autoanclaje en el modelo ex vivo porcino, tanto para cierre de una como de dos capas en todas las técnicas de cierre. Royal College of Surgeons, Londres, RU; Estudio temporal del dispositivo de cierre de heridas absorbibles Covidien V-Loc™ 180, Robert, T., Grant, M.D., MSc., FACS, New York-Presbyterian Hospital, Argent Global Services.],[ANCHOR=],[LINK=]),([FOOTNOTE=Utilization of a Porcine Model to Demonstrate the Efficacy of an Absorbable Barbed Suture for Dermal Closure, UTSW, S. Brown.],[ANCHOR=],[LINK=])

El dispositivo V-Loc™ ofrece un cierre de la incisión seguro, rápido y efectivo para sus pacientes.

En Medtronic, nuestra sólida fabricación y procesos de comprobación de la calidad aseguran que los productos innovadores que ponemos en su mano sean fiables y fáciles de usar.

Hemos estado manteniendo y mejorando los estándares de efectividad de las suturas durante muchos años. El dispositivo v-Loc™ es otro ejemplo de cómo nuestros más de 100 años de experiencia han introducido algunas de las innovaciones más importantes de las industria. Esa es una de las razones por las que los hospitales por todo el mundo cuentan con Medtronic, todos los días.

INFORMACIÓN DEL PRODUCTO
  V-Loc™ PBT wound closure device V-Loc™ 90 wound closure device V-Loc™ 180 wound closure device
Structure Unidirectional barbed monofilament Unidirectional barbed monofilament Unidirectional barbed monofilament
Suture Type Permanent Short-Term Absorbable Long-Term Absorbable
Composition Polybutester Synthetic polyester composed of glycolide, dioxanone and trimethylene carbonate Polyglyconate Copolymer of glycolic acid and trimethylene carbonate
Coating - Glycolide, Caprolactone and Calcium Stearoyl Lactylate -
Color  Blue Violet, Clear Green, Clear
Tensile Strength Permanent

7 days, 90%

14 days, 75%

7 days, 80%

14 days, 75%

21 days, 65%

Absorption Profile Permanent 90 – 110 days 180 days
Sizes 3-0, 2-0, 0, 1 4-0, 3-0, 2-0 4-0, 3-0, 2-0, 0
Indications V-Loc™ PBT non-absorbable wound closure devices are indicated for soft tissue approximation. V-Loc™ 90 absorbable wound closure devices are indicated for soft tissue approximation where use of an absorbable suture is appropriate. V-Loc™ 180 absorbable wound closure devices are indicated for soft tissue approximation where use of an absorbable suture is appropriate.
Contraindications The use of the V-Loc™ PBT nonabsorbable wound closure device is contraindicated in patients with known sensitivities or allergiesThe use of the V-Loc™ PBT nonabsorbable wound closure device is contraindicated in patients with known sensitivities or allergies to its components. V-Loc™ PBT nonabsorbable wound closure device should not be used for interrupted suture patterns. V-Loc™ PBT nonabsorbable wound closure device is not intended to be used by tying surgical knots. V-Loc™ PBT nonabsorbable wound closure device should not be used for ligating vessels or luminal structures. The use of the V-Loc™ 90 absorbable wound closure device is contraindicated in patients with known sensitivities or allergies to its components. The V-Loc™ 90 absorbable wound closure device is not for use where prolonged (beyond 2 weeks) approximation of tissues under stress is required or for fixation of permanent cardiovascular prostheses or synthetic grafts. V-Loc™ 90 absorbable wound closure device should not be used for interrupted suture patterns. V-Loc™ 90 absorbable wound closure device is not intended to be used by tying surgical knots. V-Loc™ 90 absorbable wound closure device should not be used for ligating vessels or luminal structures. The use of the V-Loc™ 180 absorbable wound closure device is contraindicated in patients with known sensitivities or allergies to its components. The V-Loc™ 180 absorbable wound closure device is not for use where prolonged (beyond 3 weeks) approximation of tissues under stress is required or for fixation of permanent cardiovascular prostheses or synthetic grafts. V-Loc™ 180 absorbable wound closure device should not be used for interrupted suture patterns. V-Loc™ 180 absorbable wound closure device is not intended to be used by tying surgical knots. V-Loc™ 180 absorbable wound closure device should not be used for ligating vessels or luminal structures.
Box Quantities 1 dozen 1 dozen 1 dozen

ORDER INFORMATION

codes beginning with:

VLOCN VLOCM VLOCL