Gynecology
From consistent, reliable, trusted vessel sealing to decades of experience surgical stapling, we offer unmatched clinical and economic value through our range of market-leading brands.
Our trusted technologies deliver performance and inspire confidence through a comprehensive approach that takes every element of patient's health into careful consideration.
Diagnose and treat intrauterine pathologies using a gentle mechanical resection.
The TruClear™ system offers a complete technology platform for the removal of a range of intrauterine pathologies.
TruClear™ hysteroscope sets optimize fluid flow and visualization when used with the TruClear™ tissue removal system. The 100% continuous flow enables controlled, precise and thorough procedures.
The HysteroLux™ system offers procedural flexibility, enhanced safety*, and optimized uterine distension.*
Modular robotic system that includes visualization and instrumentation.
The Hugo™ RAS system was designed with surgeons around the world to make more possible in robotic-assisted surgery.
Cutting, sealing and dissection for open, laparoscopic and vaginal hysterectomy, myomectomy, adnexectomy, lymphadenectomy, omentectomy and adhesiolysis.
Nonstick nano-coating enhances the performance of the LigaSure™ Maryland jaw device.1 Now you can grasp, cut, dissect, and reliably seal tissue and vessels2— with fewer interruptions from eschar buildup3,†, sticking4,‡ , and jaw cleanings3,§. So patients experience more efficient procedures.3,§
Cordless ultrasonic vessel sealing and dissection — now with a tapered, curved jaw and streamlined cleaning and sterilizationΩ
Anastomosis for colorectal resection and disc excission of endometrial lesions.
Combines powered rotation, articulation and firing in a true one-handed design. Automatically adjusts firing speed to optimise Tri-Staple™️ technology for most consistent results. Displays real-time feedback about the forces on clamp and fire to support surgical decision making.
Circular stapling now comes with Tri-Staple™ technology. That means greater leak protection5,††,‡‡ and greater perfusion allowed into the staple line.6,§§,ΩΩ
Hemostatic patches for immediate stop of bleeding and barbed sutures for c-section, vaginal cuff closure, myomectomy and sacrocolpopexy.
The Veriset™ patch is designed to address the unmet need for a simple to use, fast and highly effective hemostatic patch. It works in ~1 minute.7,†††
V-Loc™ wound closure device is an innovative technology that closes wounds securely without the need to tie knots.8,‡‡‡
Trocars for laparoscopic access.
Introducing the VersaOne™ access system, a universal trocar platform that gives you the performance, choice, and peace of mind in one complete solution.
The VersaOne™ fascial closure system is a novel all-in-one device that serves as a trocar and fascial closure device to deliver consistent port site closure and suture placement.9
* Compared to our legacy hysteroscopic fluid management system.
† Eschar buildup assessed using optical imaging analysis after 60 seal and divide cycles.
‡ Instances of tissue sticking to jaws measured over 110 seals per device.
§ Cleaning effectiveness assessed after each of two cleaning cycles.
Ω Compared to the first-generation Sonicision™ system.
†† Benchtop test results may not necessarily be indicative of clinical performance.
‡‡ Benchtop testing in porcine tissue ≤ 30 mm Hg (26 mm Hg average pressure experienced during intraoperative leak test), comparing TRIEEA31XT to Ethicon™* CDH29A (n = 20; P = 0.009).
§§ Compared to EEA™ circular staplers with DST Series™ technology.
ΩΩ Preclinical results may not correlate with clinical performance in humans.
††† Based on surgeon/customer validation. In several clinical investigations, the median times to hemostasis were within 1 - 1.5 minutes
‡‡‡ Animal data may not correlate with human clinical outcomes.
1. Refer to IFU for full list of product indications for use
2. LigaSure™ Maryland Jaw Sealer/Divider, Nano-Coated [instructions for use]. Boulder, CO: Medtronic; 2016.
3. Based on internal test report #RE00071599, LF19XX MJC marketing claims report conducted on porcine tissue. Feb. 7 to Feb. 22, 2017.
4. Based on internal test report #RE00073194 , Tissue sticking comparison of the Ethicon G2™*, Voyant™* 5 mm Fusion, LigaSure™ LF1737, and LigaSure™ LF1937 devices conducted on porcine tissue using the Force Triad™ energy platform. Jan. 18, 2017.
5. Based on internal report #RE00318260, Comparative leak testing for EEA™ circular stapler with Tri-Staple™ technology and Ethicon™* CDH. April 2021.
6. Based on internal test report #RE00265643, EEA™ circular stapler with Tri-Staple™ technology perfusion study. July 2020.
7. Öllinger R, Mihaljevic AL, Schuhmacher C, et al. A multicentre, randomized clinical trial comparing the Veriset™ hemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery [published online Dec. 27, 2012]. HPB (Oxford). 2013;15(7):548-58. doi: 10.1111/hpb.12009.
8. Zaruby J, Gingras K, Taylor J, Maul D. An in vivo comparison of barbed suture devices and conventional monofilament sutures for cosmetic skin closure: biomechanical wound strength and histology. Aesthet Surg J. 2011;31(2):232-40.
9. Based on internal validation report RE00098009 Rev A, DoubleTime VersaOne™ fascial closure system Miami lab VOC report. March 28, 2017.
You just clicked a link to go to another website. If you continue, you may go to a site run by someone else.
We do not review or control the content on non-Medtronic sites, and we are not responsible for any business dealings or transactions you have there. Your use of the other site is subject to the terms of use and privacy statement on that site.
It is possible that some of the products on the other site are not approved in your region or country.