Healthcare Professionals

ACT Plus

Automated Coagulation Timer System

ACT PLUS AUTOMATED COAGULATION TIMER SYSTEM

The ACT Plus® System combines a trusted standard in precise clot detection technology with state-of-the-art user enhancements including data management and connectivity-ready capabilities.

Overview

Blood Diagnostics and Clot Detection

In addition to running cardiopulmonary bypass, we know that you rely on accurate blood diagnostic results.

The ACT Plus® System combines a trusted standard in precise clot detection technology with state-of-the-art user features including data management and connectivity-ready capabilities. It is a microprocessor-controlled electromechanical coagulation instrument designed to determine coagulation endpoints in fresh and citrated whole blood samples. Clotting-time results are presented on the instrument’s Clot Time Display (CTD) and Liquid Crystal Display (LCD) screens.

The ACT Plus System provides long-term data storage and retrieval, with access to previous patient and quality control test data. Test results are stored in the order in which they are performed. The ability to externally transfer or save data enhances the system’s versatility.

The ACT Plus System is portable and well suited for all point-of-care testing situations. It offers the reliability required in:

  • Cardiovascular and vascular surgery
  • ECMO
  • Cardiac catheterization laboratories
  • Critical care units
  • Hemodialysis units

Manage Your ACT Plus System Data Efficiently and Effectively

As part of our ongoing commitment to helping you manage your work efficiently and effectively, we offer the ACT Plus EDM external data manager to accompany the ACT Plus Automated Coagulation Timer System.

By combining this powerful software with the ACT Plus System, you will have access to the reports you'll need to analyze test results and make informed decisions. This timesaving data management solution offers added convenience, reassurance and confidence—allowing you to stay focused on improving patient outcomes.

The ACT Plus EDM is a versatile Microsoft Access-based data management software application that runs on a PC and is designed to help you manage your patient, QC, instrument and user ID data. All aspects of Microsoft Access software required to run the application are included with the ACT Plus EDM.

Expand All

Ordering Info

Ordering Info

ACT Plus® Automated Coagulation Timer
ACT Plus Instrument
Order Number Description # of Units
ACT100 ACT Plus System is a microprocessor-controlled electromechanical coagulation instrument for determination of activated coagulation times 1 per box
ACT PLUS Disposable Test Cartridges 2-Channel Test Cartridges
402-01 Low Range Activated Clotting Time (LR ACT) - Fresh whole blood test for therapeutic heparin monitoring, post-angioplasty or dialysis 50 per box
402-02 Recalcified Activated Clotting Time (RACT) - For use with citrated whole blood samples at concentrations of 0.0 – 1.5 u/mL 50 per box
402-03 High Range Activated Clotting Time (HR ACT) - Fresh whole blood test for CV surgery, PTCA, or vascular surgery 50 per box
402-07 Heparinase Test Cartridge (HTC) - Fresh whole blood test used to identify the presence of heparin in the patient's blood sample 20 per box
ACT® CLOTtrac® Coagulation Controls
Each box contains vials of lyophilized control and 15 vials of deionized water
550-01 CLOTtrac CWB Coagulation Control - Verify performance of 402-01 and 402-02 cartridges, and the ACT Plus Instrument (when performing QC on the LR ACT cartridge (#402-01), calcium chloride (#550-11) must be added with the CLOTtrac CWB coagulation control) 15 per box
550-07 CLOTtrac HR Coagulation Control - Verify performance of 402-03, and 402-07 cartridges and the ACT Plus Instrument 15 per box
550-08 CLOTtrac HR Abnormal Coagulation Control - Verify performance of 402-03 cartridges and the ACT Plus Instrument 15 per box
550-09 CLOTtrac LR Abnormal Coagulation Control - Verify performance of 402-01 cartridges and the ACT Plus® Instrument (when performing QC on the LR ACT cartridge (#402-01), calcium chloride (#550-11) must be added with the CLOTtrac LR abnormal coagulation control) 15 per box
550-10 CLOTtrac RACT Abnormal Coagulation Control - Verify performance of 402-02 cartridges and the ACT Plus® Instrument 15 per box
550-12 CLOTtrac HTC Coagulation Control - Verify performance of 402-07 cartridges and the ACT Plus® Instrument 15 per box
550-13 CLOTtrac HR Control Pack - Verify performance of 402-03 cartridges and the ACT Plus Instrument (contains 15 HR Normal and 15 HR Abnormal) 15 per box
550-11 Calcium Chloride 5 ml vial - Use with control nos. 550-01, 550-09 in cartridge 402-01 15 per box
ACT Accessories
ACTSC ACT Plus® Bar Code Scanner 1 per box
ACTFILHR High Range ACT Easy Fill Accessory 100 per box
ACTFILLR Low Range ACT Easy Fill Accessory 100 per box
300-02 Blunt needles, 1-7/16", 19 GA 100 per box
31363 ACTtrac® Electronic Control for ACT Plus 1 per box
303-58 Actuator Cleaning Kit 1 per box
313-11 Temperature Verification Cartridge for ACT Plus® 1 per box
313-50 HEPline Kit 1 per box
ACTEDM ACT External Data Manager Software 1 per box