Overview

Maximize Viral and Bacterial Filtration in Neonatal Patients

A disposable neonatal filter designed for use with the Puritan Bennett™ 980 ventilator.

Product Features

  • Latex-free
  • Comprehensive condensate drainage system includes one-piece filter and collector vial
  • Viral and bacterial filtration efficiency of greater than 99.99%
  • Resistance to flow less than 3.0 cmH2O at 30 L/min when new
  • <0.03% penetration at 30 L/min gas flow (ISO 23328-1 method)
  • Meets CDC requirement for N100 filtration equivalency

How to Order

For additional information or to place an order, call Customer Service at +44 (0) 19 2320 2504.

Order Information
Order Code Description Unit of Measure Quantity
4-076900-00 Puritan Bennett™ Neonatal Expiratory Filtration System Case 12
Latex-free  
Recommended tidal volume and flow range Refer to the Puritan Bennett™ 980 Series Ventilator Operator's Manual  
Inlet Connector 22 mm male conical connector (ISO 5356-1)  
Viral and bacterial filtration efficiency Greater than 99.99%
Penetration Value Maximum of 0.03% penetration at 30 L/min flow (ISO 23328-1 method)
Gas leakage Less than 10 mL per minute at 100 hPa (100 cm H2O)
Pressure drop (when new) 3.0 hPa (3.0 cmH2O) at 30 L/min
Size (with condensate vial) 8.9 cm diameter x 17.8 cm long (3.5 in. diameter x 7 in. long)
Internal gas volume (with condensate vial) Approximately 110 mL
Condensate vial liquid capacity Approximately 15 mL usable volume (to maximum fill line)

Order Information

Connect with Medtronic Patient Monitoring & Respiratory Interventions
Your platform for clinical & product educational content. 

 

Medtronic announced that it has decided to keep the Patient Monitoring and Respiratory Intervention businesses as a part of Medtronic, given changing market conditions. These businesses will get increased investment and be combined and called Acute Care & Monitoring (ACM).

Medtronic also made the decision to exit the ventilator product line.

Amid evolving market conditions and a shift to lower acuity ventilators, this decision aligns with Medtronic’s strategy to concentrate resources on our market-leading positions and accelerate innovation-driven growth.

While this decision will take time and planning, we are committed to supporting our existing ventilation customers. We will continue to provide service and support throughout the ventilator life cycle, along with meeting our service contract obligations.
For more information, please visit our website.