No Image Available

Standard PTA balloons

Pacific™ Plus PTA catheter

<p>The Pacific™ Plus PTA catheter features a broad size matrix and a low profile to handle cases above the knee (ATK) or below the knee (BTK).</p>

Features

Versatility advantage

  • Short and long balloons, small and large diameters
  • Short and long shafts
  • Provides versatility to treat both ATK and BTK lesions
  • Wrap technology enables multiple inflations

Portfolio refresh for improved performance

A redesign of the 4–7 mm balloons in 2023 included:

  • Improving the catheter design to optimize introducer sheath compatibility without compromising inflation time
  • Enhancing inner and outer shaft diameter for better pushability and faster deflation times

The Pacific Plus’ shaft design provides the trackability, flexibility, and kink resistance needed to reach your destination.


This is a close-up image of the new dual middle marker bands on 200–300 mm balloons (4–7 mm) to help provide enhanced visibility for placement of the Pacific™ Plus percutaneous transluminal angioplasty (PTA) balloon.

New: dual middle marker bands provide enhanced visibility for precise placement.

Specifications

Type Specification
Catheter design Over the wire (OTW), coaxial shaft
Balloon material Proprietary
Balloon coating Hydrophilic
Balloon marker 2 or 4 swaged, platinum-iridium
Usable shaft lengths 90, 130, 150, and 180 cm
Shaft diameter 4.0 and 5.0 F
Maximum guidewire compatibility 0.018"

Ordering information

Item number Balloon diameter (mm) Balloon length (mm) Rec’d introducer sheath (F) Nominal pressure (atm) RPP (atm)
Usable length
90 cm
Usable length
130 cm
Usable length
150 cm
Usable length
180 cm
PCE 020 020 090 PCE 020 020 130 -  - 2.00 20 4 8 22
PCE 020 040 090 PCE 020 040 130 - PCE 020 040 180 2.00 40 4 8 22
PCE 020 060 090 PCE 020 060 130 - 2.00 60 4 8 22
PCE 020 080 090 PCE 020 080 130 - PCE 020 080 180 2.00 80 4 8 22
PCE 020 120 090 PCE 020 120 130 - PCE 020 120 180 2.00 120 4 8 22
PCE 020 150 090 PCE 020 150 130 - PCE 020 150 180 2.00 150 4 8 22
PCE 025 020 090 PCE 025 020 130 - 2.50 20 4 8 16
PCE 025 040 090 PCE 025 040 130 - PCE 025 040 180 2.50 40 4 8 16
PCE 025 060 090 PCE 025 060 130 - - 2.50 60 4 8 16
PCE 025 080 090 PCE 025 080 130 - PCE 025 080 180 2.50 80 4 8 16
PCE 025 120 090 PCE 025 120 130 - PCE 025 120 180 2.50 120 4 8 16
PCE 025 150 090 PCE 025 150 130 - PCE 025 150 180 2.50 150 4 8 16
PCE 030 020 090 PCE 030 020 130 - 3.00 20 4 8 16
PCE 030 040 090 PCE 030 040 130 - PCE 030 040 180 3.00 40 4 8 16
PCE 030 060 090 PCE 030 060 130 - 3.00 60 4 8 16
PCE 030 080 090 PCE 030 080 130 - PCE 030 080 180 3.00 80 4 8 16
PCE 030 120 090 PCE 030 120 130 - PCE 030 120 180 3.00 120 4 8 16
PCE 030 150 090 PCE 030 150 130 - PCE 030 150 180 3.00 150 4 8 16
PCE 035 020 090 PCE 035 020 130 - - 3.50 20 4 8 16
PCE 035 040 090 PCE 035 040 130 - - 3.50 40 4 8 16
PCE 035 060 090 PCE 035 060 130 - - 3.50 60 4 8 16
PCE 035 080 090 PCE 035 080 130 - - 3.50 80 4 8 16
PCE 035 120 090 PCE 035 120 130 - 3.50 120 4 8 16
PCE 035 150 090 PCE 035 150 130 - 3.50 150 4 8 16
PCE 040 020 090 - PCE 040 020 150 4.00 20 4 8 14
PCE 040 040 090 - PCE 040 040 150 4.00 40 4 8 14
PCE 040 060 090 - PCE 040 060 150 4.00 60 4 8 14
PCE 040 080 090 - PCE 040 080 150 4.00 80 4 8 14
PCE 040 100 090 PCE 040 100 150 - 4.00 100 4 8 14
PCE 040 120 090 - PCE 040 120 150 4.00 120 4 8 14
PCE 040 150 090 - PCE 040 150 150 - 4.00 150 4 8 14
PCE 040 200 090 - PCE 040 200 150 - 4.00  200 4 8 14
PCE 040 250 090 PCE 040 250 150 - 4.00  250 4 8 14
PCE 040 300 090 - PCE 040 300 150 - 4.00  300 8 14
PCE 050 020 090 - PCE 050 020 150 5.00 20 4 8 14
PCE 050 040 090 - PCE 050 040 150 5.00 40 4 8 14
PCE 050 060 090 - PCE 050 060 150 5.00 60 4 8 14
PCE 050 080 090 - PCE 050 080 150 5.00 80 4 8 14
PCE 050 100 090 - PCE 050 100 150 - 5.00 100 4 14
PCE 050 120 090 - PCE 050 120 150 5.00 120 4 8 14
PCE 050 150 090 PCE 050 150 150 - 5.00 150 8 14
PCE 050 200 090 - PCE 050 200 150 - 5.00 200 8 14 
PCE 050 250 090 PCE 050 250 150  5.00 250  5 8 14
PCE 050 300 090 PCE 050 300 150 5.00 300  5 14
PCE 060 020 090 - PCE 060 020 150 6.00 20 4 8 14
PCE 060 040 090 - PCE 060 040 150 6.00 40 4 8 14
PCE 060 060 090 - PCE 060 060 150 6.00 60 4 8 14
PCE 060 080 090 - PCE 060 080 150 6.00 80 4 8 14
PCE 060 100 090 - PCE 060 100 150 6.00  100 4 14 
PCE 060 120 090 - PCE 060 120 150 6.00 120 4 8 12
PCE 060 150 090 PCE 060 150 150  6.00  150  5 12 
PCE 060 200 090 PCE 060 200 150 6.00  200  12 
PCE 060 250 090 PCE 060 250 150  6.00  250  12 
PCE 060 300 090 PCE 060 300 150 6.00 300  12 
PCE 070 020 090 - PCE 070 020 150 7.00 20 4 8 12
PCE 070 040 090 - PCE 070 040 150 7.00 40 4 8 12
PCE 070 060 090 - PCE 070 060 150 7.00 60 4 8 12
PCE 070 080 090 - PCE 070 080 150 7.00 80 5 8 12
PCE 070 100 090  - PCE 070 100 150 - 7.00 100   8 12
PCE 070 120 090 - PCE 070 120 150 7.00 120 5 8 12
PCE 070 150 090  - PCE 070 150 150  - 7.00 150  12
PCE 070 200 090  - PCE 070 200 150 - 7.00  200  12 
PCE 070 250 090 - PCE 070 250 150 - 7.00   250 12

† Complications associated with radial access may include, but are not limited to abrupt vessel closure, vessel spasm, perforation or rupture of the artery, dissection, pseudoaneurysm, hematoma and thrombosis.

‡ Bench test data on file at Medtronic. Bench tests may not be indicative of clinical performance.