Healthcare Professionals
Fortrex™ HP PTA balloon catheter
for percutaneous transluminal angioplasty
Your browser is out of date
With an updated browser, you will have a better Medtronic website experience. Update my browser now.
Healthcare Professionals
Fortrex™ HP PTA balloon catheter
for percutaneous transluminal angioplasty
The Fortrex HP PTA balloon catheter is a dual-lumen catheter with a balloon that is bonded onto the distal tip. The Fortrex balloon catheter balances push and track to deliver high pressure, targeted treatment to challenging lesions. The balloon design is optimized for shape retention and peak performance at the rated burst pressure.1
The Fortrex HP PTA balloon catheter is indicated for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for stent post-dilatation in native or synthetic arteriovenous dialysis fistulae.
Instructions for Use
Find this technical manual in the product labeling supplied with each device, visit manuals.medtronic.com or call technical support for cardiovascular services: 763-526-7890.
Reference number 40 cm catheter length |
Reference number 80 cm catheter length |
Reference number 135 cm catheter length |
Balloon diameter (mm) |
Balloon length (mm) |
Nominal pressure (atm) |
Rated burst pressure (atm) |
Recommended introducer sheath (F) |
---|---|---|---|---|---|---|---|
A35HPV04020040 | A35HPV04020080 | A35HPV04020135 | 4 | 20 | 12 | 24 | 6 |
A35HPV04040040 | A35HPV04040080 | A35HPV04040135 | 4 | 40 | 12 | 24 | 6 |
A35HPV04080040 | A35HPV04080080 | A35HPV04080135 | 4 | 80 | 12 | 24 | 6 |
A35HPV04100040 | A35HPV04100080 | A35HPV04100135 | 4 | 100 | 12 | 24 | 6 |
A35HPV05020040 | A35HPV05020080 | A35HPV05020135 | 5 | 20 | 12 | 24 | 6 |
A35HPV05040040 | A35HPV05040080 | A35HPV05040135 | 5 | 40 | 12 | 24 | 6 |
A35HPV05080040 | A35HPV05080080 | A35HPV05080135 | 5 | 80 | 12 | 24 | 6 |
A35HPV05100040 | A35HPV05100080 | A35HPV05100135 | 5 | 100 | 12 | 24 | 6 |
A35HPV06020040 | A35HPV06020080 | A35HPV06020135 | 6 | 20 | 12 | 24 | 6 |
A35HPV06040040 | A35HPV06040080 | A35HPV06040135 | 6 | 40 | 12 | 24 | 6 |
A35HPV06080040 | A35HPV06080080 | A35HPV06080135 | 6 | 80 | 12 | 23 | 6 |
A35HPV06100040 | A35HPV06100080 | A35HPV06100135 | 6 | 100 | 12 | 23 | 6 |
A35HPV07020040 | A35HPV07020080 | A35HPV07020135 | 7 | 20 | 9 | 20 | 6 |
A35HPV07040040 | A35HPV07040080 | A35HPV07040135 | 7 | 40 | 9 | 20 | 6 |
A35HPV07080040 | A35HPV07080080 | A35HPV07080135 | 7 | 80 | 9 | 20 | 6 |
A35HPV07100040 | A35HPV07100080 | A35HPV07100135 | 7 | 100 | 9 | 20 | 6 |
A35HPV08040040 | A35HPV08040080 | A35HPV08040135 | 8 | 40 | 9 | 20 | 6 |
A35HPV08080040 | A35HPV08080080 | A35HPV08080135 | 8 | 80 | 9 | 19 | 6 |
A35HPV08100040 | A35HPV08100080 | A35HPV08100135 | 8 | 100 | 9 | 18 | 6 |
A35HPV09040040 | A35HPV09040080 | A35HPV09040135 | 9 | 40 | 9 | 18 | 7 |
A35HPV09080040 | A35HPV09080080 | A35HPV09080135 | 9 | 80 | 9 | 18 | 7 |
A35HPV10040040 | A35HPV10040080 | A35HPV10040135 | 10 | 40 | 8 | 16 | 7 |
A35HPV10080040 | A35HPV10080080 | A35HPV10080135 | 10 | 80 | 8 | 16 | 7 |
A35HPV12040040 | A35HPV12040080 | A35HPV12040135 | 12 | 40 | 8 | 14 | 7 |
A35HPV12080040 | A35HPV12080080 | A35HPV12080135 | 12 | 80 | 7 | 12 | 7 |
See product manual for complete, detailed product information.
Medtronic bench testing data on file.