Pacific Xtreme PTA Balloon Catheter  

Percutaneous Transluminal Angioplasty

Overview

Treat longer lesions with the Pacific™ Xtreme PTA balloon catheter OTW 0.018" that is offered in lengths from 150 to 300 mm. These balloons are well suited for use in treating long lesions in the femoral and popliteal vessels.

U.S. Indications

The Pacific Xtreme™ PTA balloon dilatation catheter in 150 mm, 200 mm, 250 mm and 300 mm balloon length is intended to dilate stenoses in femoral, popliteal and infrapopliteal arteries.

Product Details

Proprietary Shaft Design

  • For strong pushability and the kink resistance, combined with excellent flexibility

Low Profile

  • 4 F introducer sheath compatibility for less possible puncture trauma
  • Low crossing profile, reliable rewrap and safe retrieval even after multiple inflations*

Dedicated Flexitec Xtreme Balloon Material

  • For high flexibility while maintaining high RBPs

Extreme RBPs

  • For highly calcified lesions

Proprietary Technology

  • To reduce the "banana effect"

3 Shaft Lengths (90 cm, 130 cm and 180 cm)

  • For more access site options

Manuals and Technical Guides

Instructions for Use Manual
Find this technical manual in the Medtronic Manual  Library, in the product labeling supplied with each device, or by calling Medtronic at +1 763-526-7890. 

Model Specifications

Type Specification
Catheter Design Over the wire (OTW), coaxial shaft
Balloon Material Flexitec™ Xtreme
Balloon Coating LFC hydrophilic
Balloon Marker 2 swaged, Platinum Iridium
Usable Shaft Lengths 90, 130 cm
Shaft Diameter 3.9 F - 4.2 F*
Guidewire Compatibility 0.018"

*Depending on balloon size

 

Reference Number
Catheter Length
90 cm
Reference Number
Catheter Length
130 cm
Balloon
Diameter
(mm)
Balloon
Length
(mm)
Recommended
Introducer Sheath
(F)
Nominal
Pressure
(atm)
RBP
(atm)
PCU 040 150 090 PCU 040 150 130 4.0 150 4 6 14
PCU 040 200 090 PCU 040 200 130 4.0 200 4 6 14
PCU 040 250 090 PCU 040 250 130 4.0 250 4 6 14
PCU 040 300 090 PCU 040 300 130 4.0 300 4 6 14
PCU 050 150 090 PCU 050 150 130 5.0 150 4 6 14
PCU 050 200 090 PCU 050 200 130 5.0 200 4 6 14
PCU 050 250 090 PCU 050 250 130 5.0 250 5 6 14
PCU 050 300 090 PCU 050 300 130 5.0 300 5 6 14
PCU 060 150 090 PCU 060 150 130 6.0 150 5 6 12
PCU 060 200 090 PCU 060 200 130 6.0 200 5 6 12
PCU 060 250 090 PCU 060 250 130 6.0 250 5 6 12
PCU 060 300 090 PCU 060 300 130 6.0 300 5 6 12
PCU 070 150 090 PCU 070 150 130 7.0 150 5 6 12
PCU 070 200 090 PCU 070 200 130 7.0 200 5 6 12
PCU 070 250 090 PCU 070 250 130 7.0 250 5 6 1

See product catalog for complete, detailed product information.

*

Information above is supported by Bench test data which is on file at Medtronic, Inc. Test data is not indicative of clinical performance.

4 F/5 F depending on balloon size