Treat longer lesions with the Pacific™ Xtreme PTA balloon catheter OTW 0.018" that is offered in lengths from 150 to 300 mm. These balloons are well suited for use in treating long lesions in the femoral and popliteal vessels.
The Pacific Xtreme™ PTA balloon dilatation catheter in 150 mm, 200 mm, 250 mm and 300 mm balloon length is intended to dilate stenoses in femoral, popliteal and infrapopliteal arteries.
Instructions for Use Manual
Find this technical manual in the Medtronic Manual Library, in the product labeling supplied with each device, or by calling Medtronic at +1 763-526-7890.
Type | Specification |
---|---|
Catheter Design | Over the wire (OTW), coaxial shaft |
Balloon Material | Flexitec™ Xtreme |
Balloon Coating | LFC hydrophilic |
Balloon Marker | 2 swaged, Platinum Iridium |
Usable Shaft Lengths | 90, 130 cm |
Shaft Diameter | 3.9 F - 4.2 F* |
Guidewire Compatibility | 0.018" |
*Depending on balloon size
Reference Number Catheter Length 90 cm |
Reference Number Catheter Length 130 cm |
Balloon Diameter (mm) |
Balloon Length (mm) |
Recommended Introducer Sheath (F) |
Nominal Pressure (atm) |
RBP (atm) |
---|---|---|---|---|---|---|
PCU 040 150 090 | PCU 040 150 130 | 4.0 | 150 | 4 | 6 | 14 |
PCU 040 200 090 | PCU 040 200 130 | 4.0 | 200 | 4 | 6 | 14 |
PCU 040 250 090 | PCU 040 250 130 | 4.0 | 250 | 4 | 6 | 14 |
PCU 040 300 090 | PCU 040 300 130 | 4.0 | 300 | 4 | 6 | 14 |
PCU 050 150 090 | PCU 050 150 130 | 5.0 | 150 | 4 | 6 | 14 |
PCU 050 200 090 | PCU 050 200 130 | 5.0 | 200 | 4 | 6 | 14 |
PCU 050 250 090 | PCU 050 250 130 | 5.0 | 250 | 5 | 6 | 14 |
PCU 050 300 090 | PCU 050 300 130 | 5.0 | 300 | 5 | 6 | 14 |
PCU 060 150 090 | PCU 060 150 130 | 6.0 | 150 | 5 | 6 | 12 |
PCU 060 200 090 | PCU 060 200 130 | 6.0 | 200 | 5 | 6 | 12 |
PCU 060 250 090 | PCU 060 250 130 | 6.0 | 250 | 5 | 6 | 12 |
PCU 060 300 090 | PCU 060 300 130 | 6.0 | 300 | 5 | 6 | 12 |
PCU 070 150 090 | PCU 070 150 130 | 7.0 | 150 | 5 | 6 | 12 |
PCU 070 200 090 | PCU 070 200 130 | 7.0 | 200 | 5 | 6 | 12 |
PCU 070 250 090 | PCU 070 250 130 | 7.0 | 250 | 5 | 6 | 1 |
See product catalog for complete, detailed product information.
Information above is supported by Bench test data which is on file at Medtronic, Inc. Test data is not indicative of clinical performance.
4 F/5 F depending on balloon size